AI Article Synopsis

  • Researchers are developing new mechanochromic luminescent (MCL) materials from aggregation-induced emission luminogens (AIEgens) for various applications, but facing challenges due to concentration quenching effects.
  • In this study, a new class of MCL materials was created by modifying a rofecoxib skeleton with a phenyl rotator and a pair of electron donor and acceptor, resulting in tunable emission and reversible MCL behavior.
  • The materials showed unique properties such as acidochromic behavior and potential uses in anticounterfeiting, pH sensing, and LD-specific bioimaging, supported by various analysis techniques.

Article Abstract

Development of new mechanochromic luminescent (MCL) materials from aggregation-induced emission luminogens (AIEgens) has attracted wide attention due to their potential application in multiple areas. However, rational design and crafting of new MCL materials from the simple AIEgens skeleton is still a big challenge because of the undesirable concentration quenching effect. In this study, we have constructed a new class of MCL materials by adding one phenyl as a new rotator and incorporating one pair of electron donor (D) and acceptor (A) into the system of rofecoxib skeleton. This strategy endowed the compounds (-) with tunable emission behavior and some of them with the AIE effect and reversible MCL behavior. These properties may be caused by the highly twisted conformation and loosely molecular packing modes, which were elucidated clearly by analyzing the data of single-crystal X-ray diffraction, powder X-ray diffraction, and differential scanning calorimetry. Further investigation revealed that displayed acidochromic property due to the protonation of the nitrogen atom. Moreover, , as a typical compound, showed its potential applications in the area of anticounterfeiting, pH sensor, and LD-specific bioimaging.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.jpcb.1c09617DOI Listing

Publication Analysis

Top Keywords

mcl materials
12
mechanochromic luminescent
8
aggregation-induced emission
8
ld-specific bioimaging
8
x-ray diffraction
8
rofecoxib-based mechanochromic
4
materials
4
luminescent materials
4
materials investigations
4
investigations aggregation-induced
4

Similar Publications

Introduction: Acute anterior cruciate ligament (ACL) injuries can be disabling because of prolonged rehabilitation process following surgical reconstructions. Rates of ACL injuries among military service members are close to 10 times greater than the general civilian population, likely because of the operation tempo and the unique physical requirements. Studies debated functional testing requirements for return to sports, but no study investigated the impact of functional training and re-injury rates following ACL reconstruction and their association with functional testing outcomes and time to return to full duty in United States Naval Academy (USNA) Midshipmen.

View Article and Find Full Text PDF

Background: For patients having cervical spine instability, stabilization of the neck is crucial to prevent further damage to the spinal cord, which can make laryngoscopy challenging. Specialized tools like McCoy blade direct laryngoscope (Surgitech, India) and BPL video laryngoscope (BPL Medical Technologies Pvt. Ltd.

View Article and Find Full Text PDF

Antisense oligonucleotides-based approaches for the treatment of multiple myeloma.

Int J Biol Macromol

December 2024

Faculty of Medical Engineering, National University of Science and Technology Politehnica Bucharest, Gheorghe Polizu 1-7, 011061 Bucharest, Romania; Advanced Polymer Materials Group, University Politehnica of Bucharest, Gheorghe Polizu 1-7, 011061 Bucharest, Romania; ebio-Hub Research Centre, University Politehnica of Bucharest-Campus, Iuliu Maniu 6, 061344 Bucharest, Romania. Electronic address:

Multiple myeloma (MM), a hematological malignancy which affects the monoclonal plasma cells in the bone marrow, is in rising incidence around the world, accounting for approximately 2 % of newly diagnosed cancer cases in the US, Australia, and Western Europe. Despite the progress made in the last few years in the available therapeutic options (e.g.

View Article and Find Full Text PDF

Introduction: Acceptable Noise Level (ANL) is defined as the most comfortable level (MCL) intensity for speech and is calculated by subtracting the maximum noise tolerable by an individual. The ANL test has been used over time to predict hearing aid use and the impact of digital noise reduction. This study analyzes this impact by using different masker babble spectra when performing the ANL test in both hearing-impaired and healthy subjects in three different languages (Dutch, French, and Italian).

View Article and Find Full Text PDF

Tunable redox-sensitive polymeric-lipid hybrid nanocarriers (RS-PLHNCs) were fabricated using homogenization and nanoprecipitation methods. These nanocarriers were composed of novel redox-cholesterol with disulfide linkages and synthesized by conjugating cholesterol with dithiodipropionic acid esterification. Berberine (BBR) was loaded into the fabricated nanocarriers to investigate the selective uptake of BBR by cancer cells as well as its release and enhanced cytotoxicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!