Extracorporeal lung support includes the risk of hemolysis due to suction pressures. Manufacturers measure the negative suction pressure across drainage cannulas for their products in vitro using water. Clinical experience suggests that hemolysis occurs in vivo already at much lower flow rates. The aim of this study was to analyze the in vivo suction pressure for veno-venous extracorporeal membrane oxygenation (VV-ECMO) cannulas. Prospective, observational study at a tertiary-care intensive care unit: 15 patients on VV-ECMO for severe ARDS were prospectively included. In vitro , the 25 Fr drainage cannula pressure drops below a critical level of around -100 mm Hg at a flow rate of 7.9 L/min, the 23 Fr drainage cannula at 6.6 L/min. In the clinical setting, critical suction pressures were reached at much lower flow rates (5.5 and 4.7 L/min; p < 0.0001, nonlinear regression). The in vitro data largely overestimate the safely achievable flow rates in daily clinical practice by 2.4 L/min (or 44%, 25 Fr) and 1.9 L/min (or 41%, 23 Fr). In vivo measurement of suction pressure of venous drainage cannulas differed significantly from in vitro derived measurements as the latter largely underestimate the resulting suction pressure.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0000000000001668DOI Listing

Publication Analysis

Top Keywords

suction pressure
16
suction pressures
12
flow rates
12
vivo suction
8
veno-venous extracorporeal
8
extracorporeal membrane
8
membrane oxygenation
8
drainage cannulas
8
lower flow
8
drainage cannula
8

Similar Publications

The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.

View Article and Find Full Text PDF

Background: The oocyte retrieval is a critical step in assisted reproductive technologies, including in vitro fertilization and fertility preservation. Despite evolving techniques, the optimal aspiration pressure during retrieval remains debatable, with limited in vivo human studies. Existing studies, primarily in vitro and on animals, suggest that inappropriate aspiration pressures can impair oocyte quality.

View Article and Find Full Text PDF

Aim: The study compares knowledge, skills, anxiety, satisfaction and self-confidence regarding suctioning between students trained using a partial task trainer with moulage and those using a low-fidelity simulator.

Background: Moulage application in simulation has been used in nursing skills training, such as intravenous therapy, pressure ulcer and burn care, but not for suctioning.

Design: A randomized controlled study with pre-test, post-test design.

View Article and Find Full Text PDF

Passive earth pressure analysis considering hydraulic and mechanical hysteresis for unsaturated soil.

PLoS One

January 2025

Water Resources Engineering Department, College of Engineering, Salahaddin University, Erbil, Iraq.

This paper addresses the mechanical characteristics of a passive earth pressure problem taking into account water retention curve (SWRC) hysteresis. Both hydraulic (drying and wetting cycles) and mechanical hysteresis were considered. Parametric studies were carried out at various air entry values (AEV = 5-30 kPa), different wall frictions (δ = 0, 0.

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!