Extracorporeal lung support includes the risk of hemolysis due to suction pressures. Manufacturers measure the negative suction pressure across drainage cannulas for their products in vitro using water. Clinical experience suggests that hemolysis occurs in vivo already at much lower flow rates. The aim of this study was to analyze the in vivo suction pressure for veno-venous extracorporeal membrane oxygenation (VV-ECMO) cannulas. Prospective, observational study at a tertiary-care intensive care unit: 15 patients on VV-ECMO for severe ARDS were prospectively included. In vitro , the 25 Fr drainage cannula pressure drops below a critical level of around -100 mm Hg at a flow rate of 7.9 L/min, the 23 Fr drainage cannula at 6.6 L/min. In the clinical setting, critical suction pressures were reached at much lower flow rates (5.5 and 4.7 L/min; p < 0.0001, nonlinear regression). The in vitro data largely overestimate the safely achievable flow rates in daily clinical practice by 2.4 L/min (or 44%, 25 Fr) and 1.9 L/min (or 41%, 23 Fr). In vivo measurement of suction pressure of venous drainage cannulas differed significantly from in vitro derived measurements as the latter largely underestimate the resulting suction pressure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0000000000001668 | DOI Listing |
Sci Rep
January 2025
College of Geosciences and Engineering, North China University of Water Resources and Electric Power, Zhengzhou, 450046, China.
The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Obstetrics and Gynecology, Seoul National University Hospital, Seoul, South Korea.
Background: The oocyte retrieval is a critical step in assisted reproductive technologies, including in vitro fertilization and fertility preservation. Despite evolving techniques, the optimal aspiration pressure during retrieval remains debatable, with limited in vivo human studies. Existing studies, primarily in vitro and on animals, suggest that inappropriate aspiration pressures can impair oocyte quality.
View Article and Find Full Text PDFNurse Educ Pract
January 2025
Dokuz Eylül University Health Science Institute, Izmir 35340, Turkey. Electronic address:
Aim: The study compares knowledge, skills, anxiety, satisfaction and self-confidence regarding suctioning between students trained using a partial task trainer with moulage and those using a low-fidelity simulator.
Background: Moulage application in simulation has been used in nursing skills training, such as intravenous therapy, pressure ulcer and burn care, but not for suctioning.
Design: A randomized controlled study with pre-test, post-test design.
PLoS One
January 2025
Water Resources Engineering Department, College of Engineering, Salahaddin University, Erbil, Iraq.
This paper addresses the mechanical characteristics of a passive earth pressure problem taking into account water retention curve (SWRC) hysteresis. Both hydraulic (drying and wetting cycles) and mechanical hysteresis were considered. Parametric studies were carried out at various air entry values (AEV = 5-30 kPa), different wall frictions (δ = 0, 0.
View Article and Find Full Text PDFWorld J Urol
January 2025
Division of Urology, University of Montreal Hospital Center, Montreal, Canada.
Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).
Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.