Background: Femoral lengthening is associated with high complication rates often related to the type of surgical device used to perform the lengthening. The advent of intramedullary lengthening devices has promised a reduction in complications when compared with external fixation systems. The purpose of this study was to compare the clinical outcomes of femoral lengthening in children using a motorized intramedullary nail (Precice) versus an external fixation system (Taylor Spatial Frame-TSF; or Monolateral Rail System-MRS) at a single institution, single surgeon practice.
Methods: This study is a retrospective comparison of pediatric patients who had previously undergone femoral lengthening (±deformity correction). Patients ages 8 to 18 years of age were included and grouped based on whether they had undergone Precice nailing or external fixation (TSF or MRS) between 2010 and 2019.
Results: Twenty-seven patients (32 femurs) were included. Thirteen patients (15 femurs) had undergone Precice nailing and 14 patients (17 femurs) had undergone external fixation. The Precice group had significantly fewer problems, obstacles, and complications than the external fixation group, Precice 6.6%, 0%, 0%, respectively, and external fixation 47.1%, 29.4%, 0% respectively (P<0.01). Unplanned return to the operating room occurred in 4 cases, solely in the external fixation group. There were no differences in percentage of goal length achieved, Precice (mean 93.6%, range: 66.7% to 114.3%), external fixation (mean 96%, range: 76.9% to 117.5%) P=0.31 and total length achieved, Precice (mean: 44 mm, range: 20 to 80 mm), external fixation (mean: 46 mm, range: 10 to 70 mm) P=0.72. There was no difference in consolidation index, Precice (24.1 d/cm), external fixation (28.5 d/cm) P=0.36. The Precice group had a significantly shorter length of stay (mean: 2.2 d, range: 1 to 4 d), compared with the external fixation group (mean: 3.7 d, range: 2 to 8), P=0.01.
Conclusions: Femoral lengthening in children using a motorized intramedullary nail was associated with a markedly reduced rate of complications and shorter length of stay compared with external fixation.
Level Of Evidence: Level III.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BPO.0000000000002120 | DOI Listing |
The aim of the study was to compare the outcomes of bone transport in treating upper- middle vs. lower- middle tibial bone defects. Sixty-two patients with tibial infected large segmental defects treated by bone transport were analyzed retrospectively and divided into distal group (lower- middle tibial bone defects and proximal transport, n=38) and proximal group (upper- middle tibial bone defects and distal transport, n=24).
View Article and Find Full Text PDFZhongguo Gu Shang
January 2025
Department of Traumatic Othopeadics, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
Objective: Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.
Methods: Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old.
Zhongguo Gu Shang
January 2025
Unit 66322 of the People's Liberation Army, Beijing 100000, China.
Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.
Zhongguo Gu Shang
January 2025
Hebei Province Integrated Traditional Chinese and Western Medicine 3D Printing Technology Innovation Center, Cangzhou 061000, Hebei, China.
Objective: To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
Methods: Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.
Objective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!