This study aims to determine possible associations between strength parameters, injury rates, and performance outcomes over six seasons in professional basketball settings. Thirty-six male professional basketball players [mean ± standard deviation (SD): age, 30.5 ± 4.7 years; height, 199.5 ± 9.5 cm; body mass, 97.9 ± 12.9 kg; BMI 24.6 ± 2.5 kg/m] participated in this retrospective observational study, conducted from the 2008-09 to the 2013-14 season. According to their epidemiological records, each player followed an individual plan designed within different strength training programs: Functional ( = 16), Eccentric ( = 8), or Resistance ( = 12). Seven hundred and fourteen valid records were obtained from 170 individual strength tests during 31 sessions. Tests performed were leg press, squat, and jerk. Parameters recorded were force, power, velocity, peak velocity, and time to peak velocity for strength; time loss injury and muscle injury for injury rate; and games won, games lost, and championships for performance outcomes. All the strength variables and injuries are independent of the strength programs ( < 0.01). The correlation analysis showed very significant relationships between muscular injuries and time to peak velocity ( = 0.94; < 0.01), significant relationships between force and games lost ( = 0.85; < 0.05), and muscular injuries with games lost ( = -0.81; < 0.05) per season. Mean values per season described a possible association of force, time to peak velocity, and muscular injuries with performance outcomes ( = 0.96; < 0.05). In this specific context, strength variables and injury rate data show no association with a single type of strength training program in this cohort of high-performance basketball players.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8845446 | PMC |
http://dx.doi.org/10.3389/fpsyg.2021.796098 | DOI Listing |
Fluids Barriers CNS
January 2025
Adelaide Spinal Research Group & Centre for Orthopaedics and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Level 7, Adelaide Health and Medical Sciences Building, North Terrace, Adelaide, SA, 5005, Australia.
Background: Traumatic spinal cord injury (SCI) causes spinal cord swelling and occlusion of the subarachnoid space (SAS). SAS occlusion can change pulsatile cerebrospinal fluid (CSF) dynamics, which could have acute clinical management implications. This study aimed to characterise SAS occlusion and investigate CSF dynamics over 14 days post-SCI in the pig.
View Article and Find Full Text PDFJ Strength Cond Res
December 2024
School of Kinesiology, University of Michigan, Ann Arbor, Michigan.
Motlagh, JG and Lipps, DB. The contribution of muscular fatigue and shoulder biomechanics to shoulder injury incidence during the bench press exercise: A narrative review. J Strength Cond Res 38(12): 2147-2163, 2024-Participation in competitive powerlifting has rapidly grown over the past two decades.
View Article and Find Full Text PDFInt J Exerc Sci
December 2024
Exercise Science and Exercise Physiology Program, Kent State University, Kent, OH, USA.
This investigation evaluated validity and reliability of the HUMAC360 linear position transducer (LPT) compared to the Tendo Sport Weightlifting Analyzer (TENDO) for measuring mean velocity (MV), peak velocity (PV), and displacement (D) during the bench press. Seventeen recreationally active individuals completed three visits. During visit one, participants were assessed for their one repetition maximum (1RM) bench press.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Purpose: This study aimed to assess the hemodynamic changes in the vena cava and predict the likelihood of Cardiac Remodeling (CR) and Myocardial Fibrosis (MF) in athletes utilizing four-dimensional (4D) parameters.
Materials And Methods: A total of 108 athletes and 29 healthy sedentary controls were prospectively recruited and underwent Cardiac Magnetic Resonance (CMR) scanning. The 4D flow parameters, including both general and advanced parameters of four planes for the Superior Vena Cava (SVC) and Inferior Vena Cava (IVC) (sheets 1-4), were measured and compared between the different groups.
Zhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!