Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Current hole matching pixel detector (HMPD) collimators for SPECT imaging exist in two configurations: one hole per pixel (1HMPD) or four holes per pixel (4HMPD). The aim of this study was to assess the performance of a dual-layer collimator made by stacking up these two collimator types (1H/4HMDP) for low- and medium energy gamma emitters.. Analytical equations describing geometrical efficiency and full width at half maximum (FWHM) of the 1H/4HMDP collimator were derived. In addition, a fast dedicated Monte Carlo (MC) code neglecting scattering and designed for the collimator geometry was developed to assess the collimator's point spread function and to simulate planar and SPECT acquisitions.A relative agreement between analytical equations and MC simulations better than 3% was observed for the efficiency and for the FWHM. The length of the two layers was optimized to get the best spatial resolution while keeping the geometrical efficiency equal to that of the 45 mm length 1HMPD collimator. An optimized combination of the 1H/4HMPD configuration with respective hole lengths of 20 and 13 mm has been derived. For source-collimator distances above 5 cm and equal collimator geometrical efficiency, the spatial resolution of this optimal 1H/4HMDP collimator supersedes that of the 45 mm length 1HMPD collimator, and that of the 19.1 mm length 4HMPD collimator. This improvement was observed in simulations of bar phantom planar images and of hot rods phantom SPECT. Remarkably, the spatial resolution was preserved along the whole radial range within the Jaszczak phantom.The 1H/4HMDP collimator is a promising solution for CZT SPECT imaging of low- and medium energy emitters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ac5671 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!