Objective: To evaluate the effectiveness of medial buttress plate augmented hollow lag screws fixation in combination with sartorius pedicled iliac flap for the treatment of femoral neck fractures in young adults.

Methods: The clinical data of 11 young adult patients with femoral neck fractures between February 2013 and February 2019 were analyzed retrospectively. There were 7 males and 4 females with a mean age of 45 years (range, 32-58 years). Fractures were caused by falling from height in 6 cases, by traffic accident in 4 cases, and by sports injury in 1 case. There were 7 cases in the left hip and 4 cases in the right hip. The mean Pauwels angle was 64° (range, 55°-75°). All patients were treated by medial buttress plate augmented hollow lag screws fixation and sartorius pedicled iliac flap. The X-ray film of pelvis, lateral X-ray film of hip joint, CT scan and three-dimensional reconstruction of hip joint were taken after operation to assess fracture healing and position of the internal fixators. The postoperative hip function was evaluated according to the Harris score.

Results: All the incisions healed by first intention, and no complication such as incision infection and lateral femoral cutaneous nerve injury happened. Re-examination on the second day after operation showed that reduction and fixation of fractures was good. All patients were followed up 18-36 months (mean, 29 months). All fractures achieved bony union. The time of bony union was 16-23 weeks, with an average of 18.2 weeks. One patient (9.1%) got osteonecrosis of the femoral head (ONFH) at 30 months after operation. At last follow-up, Harris score was used to evaluate hip joint function, 9 cases were excellent, 1 case was good, 1 case was fair, and the excellent and good rate was 90.9%.

Conclusion: Medial buttress plate augmented hollow lag screws fixation in combination with sartorius pedicled iliac flap for the treatment of femoral neck fractures in young adults has the advantage of strong biomechanical stability and can effectively improve the blood supply of femoral head and neck, which subsequently reduce the incidence of ONFH. However, the surgical indication should be fully considered.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8863533PMC
http://dx.doi.org/10.7507/1002-1892.202108093DOI Listing

Publication Analysis

Top Keywords

medial buttress
16
buttress plate
16
plate augmented
16
augmented hollow
16
hollow lag
16
lag screws
16
screws fixation
16
sartorius pedicled
16
pedicled iliac
16
iliac flap
16

Similar Publications

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Hypothesis: Proximal humerus fractures present a treatment challenge due to varied fracture configurations and a lack of consensus on optimal management. Locking plate designs offer promising solutions, yet technical guidelines for successful outcomes remain elusive. Complications are common, with fixation-related failures often attributed to varus collapse.

View Article and Find Full Text PDF

THE SOFT TRIANGLE TENSION GRAFT.

Plast Reconstr Surg

January 2025

Private Practice, Ghavami Plastic Surgery, Beverly Hills, California.

Introduction: Rhinoplasty surgeons often rely on tip grafting in order to add volume in the infratip, mid-tip or supratip areas. The author has developed a novel tip graft, from the repurposed, pliable cephalic margins of the lower lateral cartilage lateral crura. The main purpose of the soft triangle tension graft (STTG) is to control tip tension of the medial crura, buttress the soft triangles and add a small degree of volume to the tip.

View Article and Find Full Text PDF

Background: Femoral neck fractures, particularly Pauwels type II and III, pose significant challenges due to their vertical instability and susceptibility to complications such as non-union and avascular necrosis (AVN). Medial buttress plates (MBPs) have emerged as a promising adjunct in fixation, offering biomechanical advantages by neutralizing shearing forces and enhancing stability. However, the clinical efficacy of MBPs across different fixation techniques, plate configurations, and positioning remains unclear.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!