Background: The displacement of cardiac implantable electronic devices (CIEDs) toward the caudal side during standing after CIED implantation could cause lead dislodgement. This study investigated the relationship between supine pocket position and standing CIEDs' displacement distance after the implantation.
Methods: After CIED surgeries performed at 2 hospitals between 2012 and 2020, 134 patients underwent postoperative chest x-rays in the supine and standing positions during hospitalization. To measure the displacement distance of CIEDs from the supine to the standing position, we identified the first thoracic vertebrae (Th1) in the supine position using the first rib as an index, drew a horizontal line at the lower edge of the Th1, and calculated the distance from that point to the upper edge of the CIED. The difference between measures for the two positions was compared. At the position of the pocket in the thorax in the supine position, the ratio of the distance between the thorax and the device is defined as the device thorax ratio (DTR). We examined the relationship between DTR and CIED displacement distance.
Results: In this study, we included 134 patients (53% men; median age, 79 years, body mass index, 22.3 ± 3.4; pacemaker 93%, left implantation 96%). We found that the more lateral the position of the CIED pocket, the more the CIED fell when standing (confidence interval = 0.34-0.60, P < .001).
Conclusions: The farther the CIED was implanted outside the thorax in the supine position, the more significantly the CIED was displaced in the standing position.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.14464 | DOI Listing |
Int J Sports Physiol Perform
December 2024
School of Sport Science, UiT The Arctic University of Norway, Tromsø, Norway.
Introduction: Women have generally lower body size and lean- to fat-mass ratio, lower maximal anaerobic power due to a lower muscle mass, and fewer fast-twitch fibers, although they can show higher resistance to fatigue or greater metabolic flexibility than men. These factors are well known and explain the sex differences in endurance sports such as distance running (10%-12%). Several of these factors-particularly the differences in body composition and skeletal-muscle characteristics-may directly impact vertical displacement and uphill performance.
View Article and Find Full Text PDFSci Rep
December 2024
School of Resources & Safety Engineering, Central South University, Changsha, 410083, Hunan, China.
To explore the mechanism of water inrush from the mine roof strata, a series of seepage-acoustic emission (SAE) experiments on red sandstone disc samples were carried out. The effects of the height to diameter ratio (H/D) and pore pressure on the mechanical, hydraulic and crack propagation properties of red sandstones were investigated. Test results show that, the peak load of rock samples declines with the decreasing H/D and increasing pore pressure.
View Article and Find Full Text PDFJ Bone Joint Surg Am
October 2024
Musculoskeletal Tumor Center, Department of Orthopedics, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, People's Republic of China.
Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.
View Article and Find Full Text PDFJ Colloid Interface Sci
December 2024
Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes 748, São Paulo 05508-000, Brazil. Electronic address:
In this study, kapok fiber (KF) a hollow and hydrophobic fiber, was modified with cetyltrimethylammonium bromide (CTAB) or cetylpyridinium chloride (CPC), rendering adsorbed amount of ∼0.75 × 10 mol/g. Small-angle X-ray scattering (SAXS) measurements of dry KF/CTAB and KF/CPC evidenced a periodic distance of ∼2.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Department of Ophthalmology, Université Paris Cité, Cochin Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France.
Purpose: This study aims to evaluate the efficacy of various tomographic indices, both established and novel, in predicting endothelial decompensation leading to either spontaneous corneal transplantation or transplantation following cataract surgery in patients with Fuchs endothelial corneal dystrophy (FECD).
Methods: In this cross-sectional, retrospective study, we reviewed the files of 93 eyes from 54 FECD patients undergoing regular follow-up. We recorded clinical metrics such as morning visual disturbance (MVD) and corrected distance visual acuity.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!