A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionakek30hanhi4m1nsomdssjqo0d3c8mvi): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Real-Time Polymerase Chain Reaction in COVID-19 Patients. | LitMetric

AI Article Synopsis

  • - COVID-19, caused by the SARS-CoV-2 virus, has varying diagnostic accuracy for PCR tests recommended by the CDC and WHO, which is explored in a study involving 12 confirmed patients and 590 samples.
  • - The study found that a newly designed in-house RT-qPCR primer set (iNP) demonstrated significantly better sensitivity (94.8%) and specificity (100%) compared to WHO and CDC primers, especially in sputum samples.
  • - Results highlight the need for ongoing improvements in viral detection methods, emphasizing that sputum tests are the most effective, followed by nasopharyngeal and self-collected saliva samples.

Article Abstract

Coronavirus disease 2019 (COVID-19) is a mild to severe respiratory illness caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The diagnostic accuracy of the Centers for Disease Control and Prevention (CDC)- or World Health Organization (WHO)-recommended real-time PCR (RT-qPCR) primers in clinical practice remains unproven. We conducted a prospective study on the accuracy of RT-qPCR using an in-house-designed primer set (iNP) targeting the nucleocapsid protein as well as various recommended and commercial primers. The accuracy was assessed by culturing or seroconversion. We enrolled 12 confirmed COVID-19 patients with a total of 590 clinical samples. When a cutoff value of the cycle threshold (C) was set to 35, RT-qPCRs with WHO RdRp primers and CDC N1, N2, and N3 primers showed sensitivity of 42.1% to 63.2% and specificity of 90.5% to 100% in sputum, and sensitivity of 65.2% to 69.6% and specificity of 65.2% to 69.6% in nasopharyngeal samples. The sensitivity and specificity of iNP RT-qPCR in sputum and nasopharyngeal samples were 94.8%/100% and 69.6%/100%, respectively. Sputum testing had the highest sensitivity, followed by nasopharyngeal testing (0.0193); self-collected saliva samples yielded better characteristics than oropharyngeal samples (0.0032). Our results suggest that iNP RT-qPCR has better sensitivity and specificity than RT-PCR with WHO (0.0001) or CDC (N1: 0.0012, N2: 0.0013, N3: 0.0012) primers. Sputum RT-qPCR analysis has the highest sensitivity, followed by nasopharyngeal, saliva, and oropharyngeal assays. Our study suggests that considerable improvement is needed for the RT-qPCR WHO and CDC primer sets for detecting SARS-CoV-2. Numerous research campaigns have addressed the vast majority of clinical and diagnostic specificity and sensitivity of various primer sets of SARS-CoV2 viral detection. Despite the impressive progress made to resolve the pandemic, there is still a need for continuous and active improvement of primers used for diagnosis in clinical practice. Our study significantly exceeds the scale of previously published research on the specificity and sensitivity of different primers comparing with different specimens and is the most comprehensive to date in terms of constant monitoring of primer sets of current usage. Henceforth, our results suggest that sputum samples sensitivity is the highest, followed by nasopharyngeal, saliva, and oropharyngeal samples. The CDC recommends the use of oropharyngeal specimens, leading to certain discrepancy between the guidelines set forth by the CDC and IDSA. We proved that the oropharyngeal samples demonstrated the lowest sensitivity for the detection of SARS-CoV-2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8849071PMC
http://dx.doi.org/10.1128/spectrum.00591-21DOI Listing

Publication Analysis

Top Keywords

oropharyngeal samples
12
primer sets
12
sensitivity
10
covid-19 patients
8
clinical practice
8
samples
8
652% 696%
8
nasopharyngeal samples
8
samples sensitivity
8
sensitivity specificity
8

Similar Publications

Objectives: Present a clinically challenging case of an immunocompetent 74-year-old male who presented with marked dyspnea and hemoptysis. After the airway was secured, direct laryngoscopy revealed a large, fungating, hemorrhagic mass of the left lateral pharyngeal wall and surrounding structures.

Methods: Chart review of a single patient.

View Article and Find Full Text PDF

Background And Objectives: Stroke-associated pneumonia (SAP) is the aftermath of aspiration of oropharyngeal secretions or stomach content. Mechanical ventilation and lowered immunity and consciousness facilitate the etiopathogenesis of SAP. Antibiotic prophylaxis and repeated culture and sensitivity testing dampen the drug susceptibility patterns of the pathogens.

View Article and Find Full Text PDF

Lymph node ratio (LNR) and lymph node yield (LNY) in head and neck cancer: A systematic review and meta-analysis.

J Craniomaxillofac Surg

December 2024

Department of Otolaryngology - Head and Neck Surgery, Giuseppe Fornaroli Hospital, ASST Ovest Milanese, Magenta, Milano, Italy; Doctoral Degree in Translational Research in Public Health and High Prevalence Diseases, UIB. Universitat de les Illes Balears, Palma de Mallorca, Spain.

Introduction: A growing amount of evidence points at lymph node yield (LNY) and lymph node ratio (LNR) as useful indicators in the prognostic evaluation of patients affected by head and neck squamous cell carcinoma (HNSCC) who require neck dissection. The aim of this study was to assess the importance of LNY and LNR in the prognostic evaluation of head and neck cancer patients.

Materials And Methods: Included studies were those examining LNY and/or LNR in head and neck cancer patients.

View Article and Find Full Text PDF

Predictive biomarkers of radiotherapy- related dermatitis, xerostomia, mucositis and dysphagia in head and neck cancer: A systematic review.

Radiother Oncol

December 2024

Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland; Graduate School for Health Sciences, University of Bern, Switzerland. Electronic address:

Background: Radiotherapy is essential for treating head and neck cancer but often leads to severe toxicity. Traditional predictors include anatomical location, tumor extent, and dosimetric data. Recently, biomarkers have been explored to better predict and understand toxicity.

View Article and Find Full Text PDF

is a Gram-positive opportunistic pathogen causing systemic disease in piglets around weaning age. The factors predisposing to disease are not known. We hypothesized that the tonsillar microbiota might influence disease risk via colonization resistance and/or co-infections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!