Objectives: Ultrasound is useful in predicting arteriovenous fistula (AVF) maturation, which is essential for hemodialysis in end-stage renal disease patients. We developed ultrasound software that measures circumferential vessel wall strain (distensibility) using conventional ultrasound Digital Imaging and Communications in Medicine (DICOM) data. We evaluated user-induced variability in measurement of arterial wall distensibility and upon finding considerable variation we developed and tested 2 methods for semiautomated measurement.
Methods: Ultrasound scanning of arteries of 10 subjects scheduled for AVF surgery were performed. The top and bottom of the vessel wall were tracked using the Kanade-Lucas-Tomasi (KLT) feature-tracking algorithm over the stack of images in the DICOM cine loops. The wall distensibility was calculated from the change of vessel diameter over time. Two semiautomated methods were used for comparison.
Results: The location of points selected by users for the cine loops varied significantly, with a maximum spread of up to 120 pixels (7.8 mm) for the top and up to 140 pixels (9.1 mm) for the bottom of the vessel wall. This variation in users' point selection contributed to the variation in distensibility measurements (ranging from 5.63 to 41.04%). Both semiautomated methods substantially reduced variation and were highly correlated with the median distensibility values obtained by the 10 users.
Conclusions: Minimizing user-induced variation by standardizing point selection will increase reproducibility and reliability of distensibility measurements. Our recent semiautomated software may help expand use in clinical studies to better understand the role of vascular wall compliance in predicting the maturation of fistulas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jum.15960 | DOI Listing |
Catheter Cardiovasc Interv
December 2024
Department of Surgery, University of North Dakota School of Medicine and Health Sciences, Grand Forks, North Dakota, United States.
Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.
Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.
J Cardiothorac Surg
December 2024
Beijing Children's Hospital Capital Medical University Beijing, Beijing, China.
Objective: Berry syndrome is a group of rare congenital cardiac malformations including aortopulmonary window (APW), aortic origin of the right pulmonary artery (AORPA), interruption of the aortic arch (IAA), patent ductus arteriosus (PDA) (supplying the descending aorta) and intact ventricular septum. This paper will analyze the clinical data of 7 patients with Berry syndrome who underwent surgical treatment in our institution and discuss the one-stage surgical correction of Berry syndrome in combination with the literature.
Methods: From January 2013 to July 2024, a total of 7 children with Berry syndrome were admitted to the Cardiac Surgery Department of Beijing Children's Hospital.
Methodist Debakey Cardiovasc J
December 2024
Cardiothoracic and Vascular Surgery Center, University Hospital, Mansoura University, Dakahliya, Egypt.
A 25-year-old female presented with a congenital painless growing mass on the right side of her neck with symptoms of tinnitus and difficulty breathing. Imaging revealed an aneurysm of the internal jugular vein reaching a maximum diameter of 9.2 cm, shifting the trachea and right thyroid lobe to the left side.
View Article and Find Full Text PDFJ Control Release
December 2024
MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310058, China; State Key Laboratory of Transvascular Implantation Devices, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310009, China. Electronic address:
Restenosis, the re-narrowing of blood vessels after drug-coated balloons (DCBs), remains a major clinical issue. While rapamycin is the current clinical option for preventing restenosis due to its effectiveness and low toxicity, its delivery is limited by poor tissue absorption and rapid clearance, leading to suboptimal drug retention. Here, we developed the adhesive-polyelectrolyte-coated poly(lactic-co-glycolic acid) (PLGA) particles using in-situ UV-triggered polymerization, encapsulating rapamycin.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Vascular Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!