Background: Retransplantation candidates are disadvantaged owing to lack of good-quality liver grafts. Strategies that can facilitate transplantation of suboptimal grafts into retransplant candidates require investigation. The aim was to determine whether late liver retransplantation can be performed safely with suboptimal grafts, following normothermic machine perfusion.

Methods: A prospectively enrolled group of patients who required liver retransplantation received a suboptimal graft preserved via normothermic machine perfusion. This group was compared with both historical and contemporaneous cohorts of patient who received grafts preserved by cold storage. The primary outcome was 6-month graft and patient survival.

Results: The normothermic machine perfusion group comprised 26 patients. The historical (cold storage 1) and contemporaneous (cold storage 2) groups comprised 31 and 25 patients respectively. The 6-month graft survival rate did not differ between groups (cold storage 1, 27 of 31, cold storage 2, 22 of 25; normothermic machine perfusion, 22 of 26; P = 0.934). This was despite the normothermic machine perfusion group having significantly more steatotic grafts (8 of 31, 7 of 25, and 14 of 26 respectively; P = 0.006) and grafts previously declined by at least one other transplant centre (5 of 31, 9 of 25, and 21 of 26; P < 0.001).

Conclusion: In liver retransplantation, normothermic machine perfusion can safely expand graft options without compromising short-term outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1093/bjs/znab475DOI Listing

Publication Analysis

Top Keywords

normothermic machine
28
machine perfusion
24
cold storage
20
liver retransplantation
12
perfusion group
12
liver grafts
8
suboptimal grafts
8
6-month graft
8
comprised patients
8
machine
7

Similar Publications

Normothermic machine perfusion (NMP) facilitates utilization of marginal liver allografts. It remains unknown whether clinical benefits offset additional costs in the real-world setting. We performed a comparison of outcomes and hospitalization costs for donor livers preserved by NMP versus static cold storage (SCS) at a high-volume center.

View Article and Find Full Text PDF

Background: The availability of in situ normothermic regional perfusion (NRP) or ex situ normothermic machine perfusion (NMP) has revolutionized donation after circulatory death (DCD) liver transplant (LT). While some have suggested that NRP and NMP may represent competing technologies for DCD LT, there are many scenarios where these technologies can function in a complementary manner.

Methods: Between January 2022 and March 2024, 83 DCD LTs were performed using NRP (62 NRP alone and 21 NRP + NMP) and were compared with 297 static cold storage (SCS) DCD LTs.

View Article and Find Full Text PDF

Solid organ transplantation originating from uncontrolled donation after circulatory death in Europe: a narrative review.

Scand J Trauma Resusc Emerg Med

December 2024

Emergency Department, Cliniques Universitaires Saint-Luc, Emergency Medicine, Department of Public Health and Primary Care, Faculty of Medicine, Catholic University Leuven, Brussels, Belgium.

Human organ transplantation has begun in the 1960s with donation after circulatory death. At that time this was named non heart beating donation, later donation after cardiac death and nowadays it is named donation after circulatory death. Currently, we are facing a significant shortage of transplant organs in Europe and worldwide.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!