A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Catquest-9SF questionnaire: validation of the Portuguese version using the Rasch analysis. | LitMetric

Purpose: The aim of this study was to validate the Portuguese version of Catquest-9SF through its application in a native Brazilian population with cataracts and to determine the correlation of the questionnaire scores with preoperative visual acuity.

Methods: A prospective study was conducted to validate the Catquest-9SF questionnaire, which was translated and back-translated, generating a final version in Portuguese. A total of 120 Brazilian patients awaiting cataract surgery were recruited to answer the questionnaire and to document their preoperative data and visual acuity. The Rasch analysis was used to assess the instrument's psychometric properties.

Results: The Portuguese version of Catquest-9SF demonstrated an acceptable adjustment of the items (item fit statistics ranging from 0.7 to 1.3), unidimensionality (principal component analysis), and good organization in the item response categories (thresholds of the categories: -2.79, 0.57, and 2.22, respectively). The questionnaire contains items with stable relationships if considered at the same level of visual impairment in the comparison between the two groups (absence of differential item functioning). The separation of people (person separation index, 3.07) was adequate. The visual acuity in the logarithm of the minimum angle of resolution (logMAR) in the best eye with the best optical correction showed a statistically significant correlation with the Catquest-9SF logit score (r=0.282 and p=0.004).

Conclusions: The Portuguese version of Catquest-9SF presents evidence of validity and reliability, in addition to being linguistically and culturally understandable for Portuguese-speaking patients born in Brazil. The questionnaire is easy to understand and quick to apply, as it could adequately estimate the subjective visual functioning in patients with cataracts. We found a significant correlation between visual acuity and the questionnaire score.

Download full-text PDF

Source
http://dx.doi.org/10.5935/0004-2749.20230014DOI Listing

Publication Analysis

Top Keywords

portuguese version
16
version catquest-9sf
12
visual acuity
12
catquest-9sf questionnaire
8
rasch analysis
8
catquest-9sf
6
questionnaire
6
visual
6
portuguese
5
version
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!