Development of cellulosic material-based microchannel device capable of fluorescence immunoassay of microsamples.

Anal Bioanal Chem

Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8654, Japan.

Published: May 2022

Microfluidic immunoassay devices are a promising technology that can quickly detect biomarkers with high sensitivity. Recently, many studies implementing this technology on paper substrates have been proposed for improving cost and user-friendliness. However, these studies have identified problems with the large volume of sample required, low sensitivity, and a lack of quantitative accuracy and precision. In this paper, we report a novel structure implemented as a cellulosic material-based microchannel device capable of quantitative immunoassay using small sample volumes. We fabricated microfluidic channels between a transparent cellophane film and water-resistant paper to facilitate loading of small-volume samples and reagents, with a 40-μm-wide immunoreaction matrix constructed in the center of the microchannel using highly precise photolithography. A fluorescence sandwich immunoassay for C-reactive protein (CRP) was successfully implemented that required only a 1-μL sample volume and a 20-min reaction time. We confirmed that the limit of detection of the device was 10-20 ng/mL with a coefficient of variation under 5.6%, which is a performance level comparable to conventional plastic-based human CRP enzyme-linked immunosorbent assay (ELISA) kits. We expect that such devices will lead to the elimination of large amounts of medical waste from the use of ubiquitous diagnostics, a result that is consistent with environmental sustainability goals.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-022-03963-2DOI Listing

Publication Analysis

Top Keywords

cellulosic material-based
8
material-based microchannel
8
microchannel device
8
device capable
8
development cellulosic
4
capable fluorescence
4
immunoassay
4
fluorescence immunoassay
4
immunoassay microsamples
4
microsamples microfluidic
4

Similar Publications

Detection of Hydrogen Peroxide Vapors Using Acidified Titanium(IV)-Based Test Strips.

Materials (Basel)

December 2024

Department of Chemistry, 316 Physical Science, Oklahoma State University, Stillwater, OK 74078, USA.

One method for the colorimetric detection of hydrogen peroxide vapor is based on a titanium-hydrogen peroxide complex. A color changing material based on a titania hydroxypropyl cellulose thin film was initially developed. However, as this material dries, the sensitivity of the material is significantly reduced.

View Article and Find Full Text PDF

This study presents the development and characterization of a novel nanocomposite wound dressing material based on polylactic acid (PLA) nanofibers incorporating chitosan nanocapsules loaded with chamomile extract and cellulose nanoparticles. The nanofibers were fabricated using a three-step synthesis and electrospinning techniques, resulting in uniform, bead-free fibers with an average diameter of 186 ± 56 nm. Fourier-transform infrared spectroscopy confirmed the successful incorporation of all components, while tensile strength tests demonstrated improved mechanical properties by adding nanoparticles.

View Article and Find Full Text PDF

Treating diabetic retinopathy (DR) effectively is challenging, aiming for high efficacy with minimal discomfort. While intravitreal injection is the current standard, it has several disadvantages. Implantable systems offer an alternative, less invasive, with long-lasting effects drug delivery system (DDS).

View Article and Find Full Text PDF

Hierarchical electrodes with superior cycling performance using porous material based on cellulose nanofiber as flexible substrate.

Carbohydr Polym

December 2024

Key Laboratory of Wood Material Science and Application (Beijing Forestry University), Ministry of Education, Beijing 100083, China; Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing 100083, China. Electronic address:

The development and application of flexible electrodes with extended cycle life have long been a focal point in the field of energy research. In this study, positively charged polyethylene imine (PEI) and conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) with negative charge were alternately deposited onto a cellulose nanofiber (CNF) porous material utilizing pressure gradient-assisted layer-by-layer (LbL) self-assembly technology. The flexible substrate, characterized by a three-dimensional porous structure reinforced with stiff CNF, not only facilitated high charge storage but also enhanced the electrode's cycling life by reducing the volume changes of PEDOT:PSS.

View Article and Find Full Text PDF

Ciprofloxacin (CIP) is one of the most widely used antibiotics to treat bacterial infections. Consequently, there is concern that it may contaminate water resources due to its high usage level. It is therefore necessary to monitor, trace, and reduce exposure to these antibiotic residues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!