Highly reproducible and sensitive electrochemical biosensor for Chlamydia trachomatis detection based on duplex-specific nuclease-assisted target-responsive DNA hydrogels and bovine serum albumin carrier platform.

Anal Chim Acta

Department of Laboratory Medicine, Xiamen Key Laboratory of Genetic Testing, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361005, People's Republic of China. Electronic address:

Published: March 2022

16S ribosomal-RNA (16S rRNA) is often used as an ultrasensitive marker for Chlamydia trachomatis (CT) detection because of its species specificity and high copy number in CT. Robust methods for 16S rRNA detection must be developed to realize the early diagnosis of CT infections. In this work, a highly reproducible and sensitive electrochemical biosensor based on duplex-specific nuclease (DSN)-assisted target-responsive DNA hydrogels and bovine serum albumin (BSA) carrier platform for CT detection was developed. Target rRNA can trigger the DNA hydrogel response, which causes it to be repeatedly cleaved by DSN, ultimately leading to the release of a large amount of horseradish peroxidase-labelled streptavidin (SA-HRP) embedded in the hydrogel beforehand. The released SA-HRP was stably captured by the capture probes that were orderly loaded at the gold electrode with the help of a BSA layer. Then, SA-HRP catalyzed the redox reaction of 3,3',5,5'-tetramethylbenzidine and HO, producing a current signal that can be detected. The current signal was proportional to the concentration of CT 16S rRNA from 10 fM to 25 pM with a detection limit of 5.8 fM (S/N = 3). The signal conversion function of the DNA hydrogel avoids the instability of nonhomogeneous nucleic acid hybridization on the gold electrode surface, and combined with optimization by BSA for capture probe modification, this electrochemical biosensor is highly reproducible with a relative standard deviation of 4.3% for the detection of 10 samples of the same concentration. The proposed strategy provides a highly reproducible and sensitive detection method for the extensive screening of CT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2022.339496DOI Listing

Publication Analysis

Top Keywords

highly reproducible
16
reproducible sensitive
12
electrochemical biosensor
12
16s rrna
12
sensitive electrochemical
8
chlamydia trachomatis
8
trachomatis detection
8
based duplex-specific
8
target-responsive dna
8
dna hydrogels
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!