Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A novel, rapid and simple reverse-phase high performance liquid chromatography (RP-HPLC) method for the simultaneous determination of three pesticides - mancozeb, azoxystrobin and difenoconazole by derivatization with ethyl iodide is presented. Analysis was performed on a C18 column (Agilent Eclipse plus, 150 mm × 4.6 mm; 5 μ) with the mobile phase consisting of acetonitrile + methanol (90 + 10 v/v) - water (0.1% v/v trifluoroacetic acid) (60 : 40, v/v) pumped isocratically at a flow rate of 1.0 mL min and detection wavelength of 205 nm and 272 nm. The factors affecting the derivatization reaction and separation conditions were carefully evaluated and optimized. The method was linear over the concentration range of 3.50 mg L to 31.48 mg L for mancozeb, 0.32 mg L to 2.85 mg L for azoxystrobin and 0.32 mg L to 2.89 mg L for difenoconazole. The new method was successfully applied for the analysis of mancozeb, azoxystrobin and difenoconazole in the pesticide formulation with range recoveries of 99.46% to 100.76%, 99.07% to 101.09% and 98.59% to 101.59%, respectively. The present method is suitable and favorable for the simultaneous separation and analysis of tertiary mixture analytes on account of its sensitivity, rapidity and cost-effectiveness. In addition, it could have excellent application prospects for the simultaneous determination of all three pesticides in other formulated products.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d1ay01926k | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!