Purpose: To compare the efficacy and safety between paclitaxel coated balloon (PCB) angioplasty and conventional balloon (CB) angioplasty in the treatment of dysfunctional arteriovenous fistula (AVF).
Methods: We searched four major electronic databases (PubMed, EMBASE, Web of Science and the Cochrane Library) for randomized controlled trials (RCTs) published from inception through November 28, 2021. Outcomes of interest included target lesion primary patency (TLPP), technical success and all-cause mortality. The STATA package version 15.1 was utilized to undertake meta-analyses.
Results: Fourteen RCTs totaling 1535 patients were analyzed. The available data showed that there were no significant differences of TLPP rates at 3, 6, 9 and 12 months between the PCB group and the CB group (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.93-1.07, = 1.000, = 33.5%, Cochrane test = 0.185, fixed-effect model; RR 1.17, 95% CI 0.99-1.39, = 0.065, = 75.4%, Cochrane test = 0.000, random-effect model; RR 0.81, 95% CI 0.35-1.89, = 0.625, = 62.8%, Cochrane test = 0.045, random-effect model; RR 1.19, 95% CI 0.97-1.47, = 0.096, = 40.5%, Cochrane test = 0.071, random-effect model). In addition, two groups had similar technical success rates (RR 1.00, 95% CI 0.97-1.03, = 1.000, = 0.0%, Cochrane test = 0.596, fixed-effect model) and all-cause mortality rates (RR 1.00, 95% CI 0.54-1.84, = 1.000, = 0.0%, Cochrane test = 0.599, fixed-effect model).
Conclusions: PCB angioplasty did not appear to convey any obvious advantage over CB angioplasty in the treatment of dysfunctional AVF. However, further multi-center, large-scale and well-designed RCTs are needed to prove outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8856055 | PMC |
http://dx.doi.org/10.1080/0886022X.2022.2029487 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!