: To investigate the safety and efficacy of endovascular embolization of very tiny (≤2 mm) intracranial aneurysms with single coil and summarize experience. : A retrospective analysis was performed for 15 consecutive patients with very tiny aneurysms treated by coil embolization alone or stent-assisted coil embolization between January 2017 and January 2020. 15 patients with six unruptured aneurysms and nine ruptured aneurysms were included in this study. There were eight males and seven females with a mean age of 50.0 ± 5.2 years (range 41 to 57 years old). Intraoperative complications, imaging outcomes, clinical outcomes and follow-up data were analyzed. : All aneurysms were embolized with a single coil. Lvis stents were used in all coil assisted embolizations. The embolization success rate was 100%. The average volume embolization ratio (VER) of aneurysm embolization was 53.7 ± 25.5%. An intraoperative aneurysm re-rupture complication occurred in one patient (6.7%). 11 patients (73.3%) had immediate complete occlusion after embolization. After a mean follow-up period of 6.7 ± 1.4 months, 13 patients (86.7%) had complete occlusion. No patients had aneurysm re-rupture, an ischemic event or recurrence during follow-up. All patients achieved favorable clinical outcomes with a modified rankin scale (MRS) of 0-2. : This study demonstrates that endovascular embolization of very tiny intracranial aneurysms with a single coil is safe and effective. However, the follow-up period was not long enough and studies with larger numbers of patients are required. The summary of experience reported here is expected to provide significant patient benefits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.31083/j.jin2101027 | DOI Listing |
Protein Sci
February 2025
IRR Chemistry Hub, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.
Super-resolution microscopy has revolutionized biological imaging, enabling the visualization of structures at the nanometer length scale. Its application in live cells, however, has remained challenging. To address this, we adapted LIVE-PAINT, an approach we established in yeast, for application in live mammalian cells.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
School of Information Science and Engineering, Henan University of Technology, Zhengzhou 450001, China.
Magnetic resonance imaging (MRI) is a non-invasive medical imaging technique that is widely used for high-resolution imaging of soft tissues and organs. However, the slow speed of MRI imaging, especially in high-resolution or dynamic scans, makes MRI reconstruction an important research topic. Currently, MRI reconstruction methods based on deep learning (DL) have garnered significant attention, and they improve the reconstruction quality by learning complex image features.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
Tomography
January 2025
NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.
: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.
View Article and Find Full Text PDFCarbohydr Polym
March 2025
School of Public Health, Ningxia Medical University, Yinchuan 750004, Ningxia, China. Electronic address:
Intestinal injury and microbiota disorder take part in the development of UC. In this research, we obtained an arabinogalactan (LBP-m) from Lycium barbarum and firstly characterized its physicochemical properties. LBP-m was a homogeneous polysaccharide (172 kDa) consisted of Ara, Gal, Glc, GalA, and GlcA with a mole ratio of 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!