In order to effectively detect the contact state between the operator and the collaborative robot, a sensor with excellent external force detection performance is needed. The existing force/torque sensor and joint torque sensor, which are the two main external force sensors methods in cooperative robots, have limitations; only the force exerted at the end effector is detected, and it induces a low stiffness in the overall structure which affects the control performance. In the case of sensorless collision detection methods that utilize the current sensor that is used for motor control, the estimation of the performance of external force is sensitive to the sensor noise and dynamic model accuracy only to the extent that it can be used for collision detection. In this paper, we propose a strain gauge-based three-axis sensor of a cylindrical shape, which is often used as a link in a robot. By integrating sensors with robot links, the external force can be precisely measured without compromising the stiffness and is decoupled with joint disturbances, such as motor friction. Sensor calibration is conducted using static load evaluation equipment, and the reliability of collision detection is confirmed by comparing the theoretical/structural analysis results. Through the weight test and sensor characteristic evaluation, the performance and output stability are validated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840688PMC
http://dx.doi.org/10.3390/s22031222DOI Listing

Publication Analysis

Top Keywords

collision detection
16
external force
16
sensor
9
three-axis sensor
8
excellent external
8
external
5
detection
5
force
5
development robot
4
robot arm
4

Similar Publications

IEEE 802.11 is one of the most common medium access control (MAC) protocols used in wireless networks. The carrier sense multiple access with collision avoidance (CSMA/CA) mechanisms in 802.

View Article and Find Full Text PDF

Joint communication and sensing (JCS) is becoming an important trend in 6G, owing to its efficient utilization of spectrums and hardware resources. Utilizing echoes of the same signal can achieve the object location sensing function, in addition to the V2X communication function. There is application potential for JCS systems in the fields of ADAS and unmanned autos.

View Article and Find Full Text PDF

Conjugation of short-chain fatty acids (SDFAs) to amines containing ring structures allows for better measurement by liquid chromatography tandem mass spectroscopy (LC-MS/MS). However, collision-induced dissociation (CID) results in breaking the conjugate back to the original SCFA and amine. We therefore set out to find an amine that would remain on the SCFA after CID and create a unique daughter for selectivity of measurement.

View Article and Find Full Text PDF

Enhanced Electrochemiluminescence from Ruthenium-Tagged Immune Complex at Flexible Chains for Sensitive Analysis of Glutamate Decarboxylase Antibody.

Biosensors (Basel)

January 2025

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China.

Herein, a sensitive electrochemiluminescence (ECL) immunosensor is designed by immobilizing ruthenium-tagged immune complexes at flexible poly-ethylene-glycol (PEG) chains on the electrode surface, which offers more freedom for the collision of the ruthenium complex at the electrode during the initial ECL reaction. The electrochemical characterizations confirm the loose structure of the assembled layer with the immune complex, providing an increase in the current and the resultant enhanced ECL emissions. Comparing the sensors with the rigid structure, a 34-fold increase in the maximal ECL emission is recorded when PEG3400 is used as a linker.

View Article and Find Full Text PDF

Automatic path planning for pelvic fracture reduction with multi-degree-of-freedom.

Comput Methods Programs Biomed

January 2025

Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Beijing, China.

Background And Objectives: Computer-assisted orthopedic surgical techniques and robotics has improved the therapeutic outcome of pelvic fracture reduction surgery. The preoperative reduction path is one of the prerequisites for robotic movement and an essential reference for manual operation. As the largest irregular bone with complicated morphology, the rotational motion of pelvic fracture fragments impacts the reduction process directly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!