A Setup for Camera-Based Detection of Simulated Pathological States Using a Neonatal Phantom.

Sensors (Basel)

Chair for Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany.

Published: January 2022

Premature infants are among the most vulnerable patients in a hospital. Due to numerous complications associated with immaturity, a continuous monitoring of vital signs with a high sensitivity and accuracy is required. Today, wired sensors are attached to the patient's skin. However, adhesive electrodes can be potentially harmful as they can damage the very thin immature skin. Although unobtrusive monitoring systems using cameras show the potential to replace cable-based techniques, advanced image processing algorithms are data-driven and, therefore, need much data to be trained. Due to the low availability of public neonatal image data, a patient phantom could help to implement algorithms for the robust extraction of vital signs from video recordings. In this work, a camera-based system is presented and validated using a neonatal phantom, which enabled a simulation of common neonatal pathologies such as hypo-/hyperthermia and brady-/tachycardia. The implemented algorithm was able to continuously measure and analyze the heart rate via photoplethysmography imaging with a mean absolute error of 0.91 bpm, as well as the distribution of a neonate's skin temperature with a mean absolute error of less than 0.55 °C. For accurate measurements, a temperature gain offset correction on the registered image from two infrared thermography cameras was performed. A deep learning-based keypoint detector was applied for temperature mapping and guidance for the feature extraction. The presented setup successfully detected several levels of hypo- and hyperthermia, an increased central-peripheral temperature difference, tachycardia and bradycardia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838518PMC
http://dx.doi.org/10.3390/s22030957DOI Listing

Publication Analysis

Top Keywords

neonatal phantom
8
vital signs
8
absolute error
8
setup camera-based
4
camera-based detection
4
detection simulated
4
simulated pathological
4
pathological states
4
neonatal
4
states neonatal
4

Similar Publications

Shadow Shield Whole Body Counter (SSWBC) is used to estimate internal dose of radiation workers due to the intake of fission and activation products. The SSWBC geometry was numerically modelled in FLUKA code. The computational model was validated by comparing the experimental and simulated counting efficiencies (CEs), also known as response, using Bhabha Atomic Research Centre (BARC) reference BOttle Mannequin Absorption (BOMAB) phantom.

View Article and Find Full Text PDF

Age-specific DRLs for pediatric brain CT: A review for exploring the practices in Saudi Arabia.

Appl Radiat Isot

March 2025

Applied Physics and Radiation Technologies Group, CCDCU, School of Engineering and Technology, Sunway University, Bandar Sunway, Selangor, 47500, Malaysia; Faculty of Graduate Studies, Daffodil International University, Daffodil Smart City, Birulia, Savar, Dhaka, 1216, Bangladesh; Department of Physics, College of Science, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea. Electronic address:

Article Synopsis
  • The review investigates the establishment of diagnostic reference levels (DRLs) for pediatric brain CT scans in Saudi Arabia and compares them with data from nine other countries.
  • The findings reveal significant differences in CT doses, particularly concerning age groups, with specific DRLs provided for Saudi children aged 0-5 years and 6-15 years.
  • The study highlights the need for age-specific DRLs to enhance radiation safety and recommends adopting global standards while acknowledging limitations like inconsistencies in age classifications and restricted literature access.
View Article and Find Full Text PDF

Vacuum-assisted delivery (VAD) uses a vacuum cup on the fetal scalp to apply traction during uterine contractions, assisting complicated vaginal deliveries. Despite its widespread use, VAD presents a higher risk of neonatal morbidity compared to natural vaginal delivery and biomechanical evidence for safe VAD traction forces is still limited. The aim of this study is to develop and assess the feasibility of an experimental VAD testing setup, and investigate the impact of traction forces on fetal brain deformation.

View Article and Find Full Text PDF

Specific Absorbed Fractions for Reference Paediatric Individuals.

Ann ICRP

December 2023

Approved by the Commission in March 2023.

The calculation of doses to organs and tissues of interest due to internally emitting radionuclides requires knowledge of the time-dependent distribution of the radionuclide, its physical decay properties, and the fraction of emitted energy absorbed per mass of the target. The latter property is quantified as the specific absorbed fraction (SAF). This publication provides photon, electron, alpha particle, and neutron (for nuclides undergoing spontaneous fission) SAF values for the suite of reference individuals.

View Article and Find Full Text PDF

Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations.

Radiol Phys Technol

November 2024

Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan.

Article Synopsis
  • The air-gap method is a technique used in medical imaging that creates a space of air between the radiation source and the patient to minimize radiation scattering and improve dose distribution.
  • This study focused on evaluating the effectiveness of the air-gap method in reducing radiation exposure for pediatric patients undergoing computed tomography (CT) scans, using a specific neonate phantom and a 64 detector-row CT scanner.
  • Results showed that the air-gap method reduced exposure dose and image noise by approximately 10% and 15%, respectively, compared to conventional methods, indicating its potential benefits in pediatric imaging (p < 0.05).
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!