Arthroscopic Anatomic Glenoid Reconstruction With Distal Tibial Allograft and Hybrid Fixation.

Arthrosc Tech

Department of Surgery, Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada.

Published: February 2022

Glenoid grafting is the standard surgical treatment for recurrent shoulder instability with significant glenoid bone loss. Arthroscopic anatomic glenoid reconstruction using a distal tibial allograft for anatomic glenoid reconstruction has recently been gaining attention. This article describes the use of a hybrid graft fixation technique with 1 suture-EndoButton device and 1 compression screw in arthroscopic anatomic glenoid reconstruction using distal tibial allograft.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8821031PMC
http://dx.doi.org/10.1016/j.eats.2021.10.001DOI Listing

Publication Analysis

Top Keywords

anatomic glenoid
16
glenoid reconstruction
16
arthroscopic anatomic
12
reconstruction distal
12
distal tibial
12
tibial allograft
12
glenoid
6
reconstruction
4
allograft hybrid
4
hybrid fixation
4

Similar Publications

Background: The humeral head resurfacing arthroplasty (HHR) is normally used as a hemi shoulder arthroplasty and has been in use for the treatment of Gleno-Humeral osteoarthritis (OA) of the shoulder for more than 30 years. Some studies, however, shows that anatomical total shoulder arthroplasty provides better improvement in function than a HHR for patients with OA. Reasons for this may be a progressive glenoid wear (GW) or loosening of the HHR.

View Article and Find Full Text PDF

Introduction: Reverse shoulder arthroplasty (RSA) and anatomic total shoulder arthroplasty (TSA) are well-known methods of treating glenohumeral arthritis, which often leads to posterior wear of the glenoid. This study compared minimum two-year outcome measures in patients treated with RSA and TSA for Walch B2 and B3 glenoids.

Methods: Thirty-eight shoulders underwent TSA and 40 shoulders underwent RSA by two fellowship-trained shoulder surgeons at a tertiary referral center.

View Article and Find Full Text PDF

Humeral and Glenoid Component Malposition in Revision Shoulder Arthroplasty: A Retrospective, Cross-sectional Study.

J Shoulder Elbow Surg

January 2025

Department of Orthopedic Surgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, SUNY, Buffalo, NY, USA.

Background: The purpose of this study was to assess the incidence of glenoid and humeral component malposition in failed primary shoulder arthroplasty requiring revision. We hypothesized that glenoid and humeral component malposition would be a prevalent feature in cases requiring revision arthroplasty for primary anatomic TSA, primary RSA, and primary hemiarthroplasty procedures.

Methods: A retrospective cross-sectional study was performed focusing on identifying the incidence of malpositioned components in shoulder arthroplasty in quantitative and qualitative reviews.

View Article and Find Full Text PDF

Background: While stress shielding and adaptive bone changes around the humeral component are often observed after shoulder arthroplasty, the potential causative factors and clinical significance of these findings at mid-term follow-up have not been well elucidated. The purpose of this study was to investigate the frequency, patterns and clinical significance of radiographic findings around the humeral component of total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) at minimum 4-year follow-up.

Methods: The 6-week and minimum 4-year radiographs of patients who underwent HA and TSA were evaluated for filling ratios, changes in the humeral bone surrounding the component, and component shift or subsidence.

View Article and Find Full Text PDF

Background: Anatomic total shoulder arthroplasty are highly successful procedures for treatment of glenohumeral arthritis to reduce pain, improve range of motion, and overall quality of life. However, the long-term survivorship of the implant systems is less widely documented in the existing literature. The purpose of this study was to establish the long-term patient outcomes and identify factors influencing the postoperative implant survivorship of total anatomic shoulder arthroplasty devices/procedures utilizing the short-stemmed prosthesis and hybrid glenoid components of the Comprehensive Shoulder System (Zimmer Biomet, Warsaw, IN, USA) at an average of ten years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!