Background: Perianal Crohn's fistula and their response to anti-tumour necrosis factor (TNF) therapies are best assessed with magnetic resonance imaging (MRI), but radiologist reporting is subjective and variable. This study investigates whether segmentation software could provide precise and reproducible objective measurements of fistula volume.

Methods: Retrospective analysis of patients with perianal Crohn's fistula at our institution between 2007 and 2013. Pre- and post-biologic MRI scans were used with varying time intervals. A total of two radiologists recorded fistula volumes, mean signal intensity and time taken to measure fistula volumes using validated Open Source segmentation software. A total of three radiologists assessed fistula response to treatment (improved, worse or unchanged) by comparing MRI scans.

Results: A total of 18 cases were reviewed for this pilot study. Inter-observer variability was very good for volume and mean signal intensity; intra-class correlation (ICC) 0.95 [95% confidence interval (CI) 0.91-0.98] and 0.95 (95% CI 0.90-0.97) respectively. Intra-observer variability was very good for volume and mean signal intensity; ICC 0.99 (95% CI 0.97-0.99) and 0.98 (95% CI 0.95-0.99) respectively. Average time taken to measure fistula volume was 202 s and 250 s for readers 1 and 2. Agreement between three specialist radiologists was good [kappa 0.69 (95% CI 0.49-0.90)] for the subjective assessment of fistula response. Significant association was found between objective percentage volume change and subjective consensus agreement of response ( = 0.001). Median volume change for improved, stable or worsening fistula response was -67% [interquartile range (IQR): -78, -47], 0% (IQR: -16, +17), and +487% (IQR: +217, +559) respectively.

Conclusion: Quantification of fistula volumes and signal intensities is feasible and reliable, providing an objective measure of perianal Crohn's fistula and response to treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8832291PMC
http://dx.doi.org/10.1177/1756284818793609DOI Listing

Publication Analysis

Top Keywords

fistula response
20
perianal crohn's
16
crohn's fistula
12
fistula volumes
12
signal intensity
12
fistula
11
magnetic resonance
8
resonance imaging
8
segmentation software
8
volumes signal
8

Similar Publications

Invasive mucormycosis is an aggressive fungal infection characterized by rapid progression, primarily impacting immunocompromised individuals. Herein, we report a case of splenic infarction in association with gastrointestinal fistula and brain abscess as a rare presentation of mucormycosis biopsy, proven in a 56-year-old patient diagnosed with acute myeloid leukemia. The patient initially sought medical attention with a 3-week history of fever, night sweats, and malaise.

View Article and Find Full Text PDF

Introduction: Complex perianal fistula, which is characterized by high occurrence and is difficult to treat with current surgical techniques, negatively affects the life quality of patients. Mesenchymal stem cells (MSCs) have emerged as a new innovative therapy in recent years due to their potent anti-inflammatory and immunomodulatory properties. Considering the high recurrence rate of complex perianal fistula, we performed this systematic review and meta-analysis to assess the long-term effects of MSCs on complex perianal fistula.

View Article and Find Full Text PDF

Autologous Microfragmented Adipose Tissue Injection in Refractory Complex Crohn's Perianal Fistulas: Long-Term Results at 6.7 Years Mean Follow-up.

Inflamm Bowel Dis

December 2024

Department of Medical and Surgical Sciences, Surgery of the Alimentary Tract, IRCCS S. Orsola-Malpighi Hospital, DIMEC, University of Bologna, Bologna, Italy.

Background: Nowadays, there is a clear need for new viable therapeutic options to face complex perianal Crohn's disease (PCD). Results of our previous pilot study demonstrated the efficacy and safety of local injection of autologous microfragmented adipose tissue (MFat) in this setting. This study aims to evaluate the long-term follow-up results in the same cohort of patients.

View Article and Find Full Text PDF

Introduction: Chemoradiotherapy with MRI-guided brachytherapy boosts is the standard of care for locally advanced cervical cancer. Data from the RetroEMBRACE and EMBRACE I trials provide dose-response curves for target volumes and OAR. This study evaluated plan quality, safety and toxicity following escalation of the CTV_HR D90 prescription from 80-90 Gy to 85-95 Gy for two different applicator designs.

View Article and Find Full Text PDF

Background: There is an ongoing debate about the most appropriate method for reconstructing the pancreas after a pancreaticoduodenectomy (PD). This study assessed the impact of pancreaticogastrostomy (PG) with an external pancreatic stent on postoperative outcomes following PD in high-risk patients.

Patients And Methods: This study involves a propensity score-matched analysis of high-risk patients who underwent PD with PG reconstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!