A numerical evaluation of a novel recovery fresh air heat pump concept for a generic electric bus.

Appl Therm Eng

Bamford Bus Company Ltd T/A Wrightbus, Ballymena BT42 1SA, UK.

Published: June 2022

AI Article Synopsis

Article Abstract

Since the outbreak of the worldwide COVID-19 pandemic, public transportation networks have faced unprecedented challenges and have looked for practical solutions to address the rising safety concerns. It is deemed that in confined spaces, operating heating units (and cooling) in non-re-circulation mode ( all-fresh air mode) could reduce the airborne transmission of this infectious disease, by reducing the density of the pathogen and exposure time. However, this will expectedly increase the energy demand and reduce the driving range of electric buses. To tackle both the airborne transmission and energy efficiency issues, in this paper a novel recovery heat pump concept, operating in all-fresh air mode, was proposed. The novelty of this concept lies in its potential to be applied to already manufactured/in-service heat pump units as it does not require any additional components or need for redesigning the heating systems. In this concept, the cabin exhaust air is directed to pass through the evaporator of the heat pump system to recover part of the waste heat from the cabin and to improve the efficiency of the system. In this paper, a 0D/1D coupled model of a generic single-deck cabin and a heat pump system was developed in the Simulink environment of MATLAB (R2020b) software. The model was run in two different modes, namely the all-fresh air (as a baseline and a recovery heat pump concepts), and the air re-circulation mode (as a conventional heat pump concept with a 50% re-circulation ratio). The performance of these concepts was investigated to evaluate how an all-fresh air policy could affect the performance of the system, as well as the energy-saving potential of the proposed recovery concept. The performance of the system was studied under different ambient temperatures of -5 °C, 0 °C, and 5 °C, and for low and moderate occupancy levels. Results show that implementing the all-fresh air policy in the recovery and baseline concepts significantly improved the ventilation rate per person by at least 102% and at most 125%, compared to the air-re-circulating heat pump. Moreover, adopting the recovery concept reduced the power demand by at least 8% and at most 11%, compared to the baseline all-fresh air heat pump, for the selected fan and blower flow rates. The presented results in this paper along with the applicability of this concept to in-service mobile heat pumps could make it a feasible, practical, and quick trade-off solution to help the bus operators to protect people and improve the energy efficiency of their service.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8820066PMC
http://dx.doi.org/10.1016/j.applthermaleng.2022.118181DOI Listing

Publication Analysis

Top Keywords

heat pump
36
all-fresh air
24
pump concept
12
heat
11
air
9
pump
9
novel recovery
8
air heat
8
concept
8
air mode
8

Similar Publications

Air-source heat pumps are popular in buildings to provide cooling and heating. However, how the air discharged by air-source heat pump outdoor units affects the dispersion of air pollutants in urban street canyons remains poorly understood. This study used coupled simulations to examine the effects that air-source heat pump outdoor units had on vehicle-induced indoor and outdoor air pollution in an urban street canyon and how these effects varied based on the arrangement of outdoor units or the presence of building envelope components (e.

View Article and Find Full Text PDF

Nanosecond Nanothermometry in an Electron Microscope.

Nano Lett

January 2025

University Paris-Saclay, CNRS, Laboratoire de Physique des Solides, Orsay 91405, France.

Thermal transport in nanostructures plays a critical role in modern technologies. As devices shrink, techniques that can measure thermal properties at nanometer and nanosecond scales are increasingly needed to capture transient, out-of-equilibrium phenomena. We present a novel pump-probe photon-electron method within a scanning transmission electron microscope (STEM) to map temperature dynamics with unprecedented spatial and temporal resolutions.

View Article and Find Full Text PDF

Maintaining an optimal indoor thermal environment is crucial for enhancing the welfare and productivity of livestock in intensive breeding farms. This paper investigated the application of a combined geothermal heat pump with a precision air supply (GHP-PAS) system for cooling dairy cows on a dairy farm. The effectiveness of the GHP-PAS system in mitigating heat stress in lactating dairy cattle, along with its energy performance and local cooling efficiency in the free stalls were evaluated.

View Article and Find Full Text PDF

In the context of global efforts toward energy transition and carbon neutrality, thermal integrated pumped thermal energy storage (TIPTES) systems, especially those utilizing low-grade heat sources, have garnered significant attention due to their large capacity, flexibility, and environmental advantages. This paper explores a TIPTES system that harnesses industrial waste heat as a heat source. The system's heat pump (HP) subcycle and Organic Rankine Cycle (ORC) subcycle are equipped with regenerators to optimize system configuration and enhance efficiency.

View Article and Find Full Text PDF

The ion drag pump, as one kind of electrohydrodynamic pump, has received considerable attention in fluid applications due to its excellent pumping flow rate and pressure. However, there is a lack of systematic research about the factors that influence pumping performance of the ion drag pump. Here, a photo-induced ion drag pump based on the PLZT ceramic is proposed by combining the photoelectric effect and field emission phenomenon.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!