A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improving Patient Safety in a High-Volume Intravitreal Injection Clinic. | LitMetric

Objective: To determine the root causes of patient safety events in a high-volume intravitreal injection clinic and to assess the effect of interventions to reduce the rate of events.

Design: Quality improvement study.

Subjects: All cases of intravitreal injection in a designated injection clinic between January 1, 2016, and December 31, 2019.

Methods: The injection clinic model involved an injecting physician, who usually differed from a prescribing physician. The procedural injection area was also physically separate from the retina outpatient clinic. A root cause analysis was used to determine the factors that contributed to possible patient safety events in an institutional quality improvement project. Specific interventions were implemented to address each specific root cause. The rates of patient safety events (never events and near misses), whether associated with patient harm or not, were compared before and after the intervention.

Main Outcome Measures: Frequency (%) of patient-safety-related intravitreal injection events before (January 1, 2016, to December 31, 2018) and after (January 1, 2019, to December 31, 2019) intervention.

Results: The root cause analysis included complex treatment plans that could be difficult to interpret, insufficient time to adequately review the designated treatment plans, and the risk of human error given the pace and volume of scheduled injections. Quality improvement strategies included revising the standardized treatment plan documentation template, scheduling block time for injecting physicians to review treatment plans within 24 hours of the injection clinic, and requiring agreement between dual, independent, site, and medication verifications of the treatment plan by the injecting physician and an allied health coordinator before site marking. The rate of events was 0.1% (28 in 27 400, or 9.3 events per year) before intervention and decreased to 0.01% (1 in 9375, or 1 event per year) after intervention (P = 0.01). Most events were classified as near misses, and there were no instances of patient harm.

Conclusions: A high level of patient safety can be achieved in a complex, high-volume intravitreal injection practice by recognizing potential safety issues and root causes and implementing relevant quality improvements. Although most events were near misses and no patients were harmed, reducing near misses can reduce the likelihood of harm associated with never events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.oret.2022.02.002DOI Listing

Publication Analysis

Top Keywords

patient safety
20
intravitreal injection
20
injection clinic
20
high-volume intravitreal
12
safety events
12
quality improvement
12
treatment plans
12
events
10
injection
9
january 2016
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!