Primary aromatic amines derived carbon dots (PAA-CDs) with the protonated amino groups and high quantum yield of 46% were favorably obtained by one-step solvothermal treatment of m-phenylenediamine (m-PDA) in acidic environment. The interaction between the PAA-CDs and nitrite (NO) was inherited the characteristic reaction of m-PDA (a primary aromatic amine) and NO, resulting in strong fluorescence quenching and obvious absorption variation of the PAA-CDs. Meanwhile, a chromogenic reaction of diazo coupling can cause significant color changes. Hence, the PAA-CDs were developed for an optical dual-mode and smartphone imaging sensor for NO detection in the range of 3.0 ~ 40.0 μM with high selectivity, good sensitivity, and excellent anti-interference capability. A limit of detection (LOD) of 0.024 μM and 0.16 μM was implemented by fluorometry and colorimetry, respectively. For smartphone imaging colorimetry, the LODs of 0.46 μM (visible color) and 0.99 μM (fluorescence color) were acquired. More importantly, the established sensor has been successfully applied for the dynamic detection of NO in various food samples with the satisfying results. A smartphone imaging colorimetry method based on the CDs was firstly proposed to visually and quantitatively detect NO, which will broaden the application range of the CDs in food safety inspection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2022.128393DOI Listing

Publication Analysis

Top Keywords

smartphone imaging
16
primary aromatic
12
aromatic amines
8
amines derived
8
derived carbon
8
carbon dots
8
optical dual-mode
8
dual-mode smartphone
8
diazo coupling
8
imaging colorimetry
8

Similar Publications

Children's Acceptance of Intraoral Cameras and Smartphones for Caries Detection: A Randomized Controlled Clinical Trial.

Int J Paediatr Dent

December 2024

Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Background: Teledentistry can improve access to care, but children's acceptance of different imaging techniques is underexplored.

Aim: The aim of this study was to assess children's acceptance of intraoral cameras and smartphones for caries detection.

Design: A randomized controlled trial was conducted in rural Egyptian nurseries, with children aged ≤ 6 years randomized into intraoral camera or smartphone groups.

View Article and Find Full Text PDF

In recent years, interest in applying deep learning (DL) to medical diagnosis has rapidly increased, driven primarily by the development of Convolutional Neural Networks and Transformers. Despite advancements in DL, the automated diagnosis of skin cancer remains a significant challenge. Emulating dermatologists, deep learning approaches using clinical images acquired from smartphones and considering patient lesion information have achieved performance levels close to those of specialists.

View Article and Find Full Text PDF

Spot test with smartphone digital image analysis for determination of methadone in exhaled breath condensate.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran; Infectious and Tropical Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address:

In this work, we explored the potential of the spot test combined with image analysis using smartphones as a rapid, simple, low-cost, and environmentally friendly method for identifying methadone concentration. Herein, a carbon-gold nanocomposite has been used to generate color variation at different concentrations of methadone. The data obtained from the digital image colorimetric method was compared with those from the UV-Vis spectroscopy as a standard technique.

View Article and Find Full Text PDF

The coronavirus disease 2019 pandemic has underscored the limitations of traditional diagnostic methods, particularly in ensuring the safety of healthcare workers and patients during infectious outbreaks. Smartphone-based digital stethoscopes enhanced with artificial intelligence (AI) have emerged as potential tools for addressing these challenges by enabling remote, efficient, and accessible auscultation. Despite advancements, most existing systems depend on additional hardware and external processing, increasing costs and complicating deployment.

View Article and Find Full Text PDF

Background: Knowing the available dental space in a patient is crucial for orthodontists to develop a good treatment plan.

Objectives: To compare and evaluate the reliability, reproducibility, and accuracy of three measurement methods on models: conventional, mobile app, and digital software.

Materials And Methods: Maxillary and mandibular dental plaster models of 20 subjects with permanent dentition were analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!