Local aortic aneurysm wall expansion measured with automated image analysis.

JVS Vasc Sci

Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pa.

Published: December 2021

Background: Assessment of regional aortic wall deformation (RAWD) might better predict for abdominal aortic aneurysm (AAA) rupture than the maximal aortic diameter or growth rate. Using sequential computed tomography angiograms (CTAs), we developed a streamlined, semiautomated method of computing RAWD using deformable image registration (dirRAWD).

Methods: Paired sequential CTAs performed 1 to 2 years apart of 15 patients with AAAs of various shapes and sizes were selected. Using each patient's initial CTA, the luminal and aortic wall surfaces were segmented both manually and semiautomatically. Next, the same patient's follow-up CTA was aligned with the first using automated rigid image registration. Deformable image registration was then used to calculate the local aneurysm wall expansion between the sequential scans (dirRAWD). To measure technique accuracy, the deformable registration results were compared with the local displacement of anatomic landmarks (fiducial markers), such as the origin of the inferior mesenteric artery and/or aortic wall calcifications. Additionally, for each patient, the maximal RAWD was manually measured for each aneurysm and was compared with the dirRAWD at the same location.

Results: The technique was successful in all patients. The mean landmark displacement error was 0.59 ± 0.93 mm with no difference between true landmark displacement and deformable registration landmark displacement by Wilcoxon rank sum test ( = .39). The absolute difference between the manually measured maximal RAWD and dirRAWD was 0.27 ± 0.23 mm, with a relative difference of 7.9% and no difference using the Wilcoxon rank sum test ( = .69). No differences were found in the maximal dirRAWD when derived using a purely manual AAA segmentation compared with using semiautomated AAA segmentation ( = .55).

Conclusions: We found accurate and automated RAWD measurements were feasible with clinically insignificant errors. Using semiautomated AAA segmentations for deformable image registration methods did not alter maximal dirRAWD accuracy compared with using manual AAA segmentations. Future work will compare dirRAWD with finite element analysis-derived regional wall stress and determine whether dirRAWD might serve as an independent predictor of rupture risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8802047PMC
http://dx.doi.org/10.1016/j.jvssci.2021.11.004DOI Listing

Publication Analysis

Top Keywords

image registration
16
aortic wall
12
deformable image
12
landmark displacement
12
aortic aneurysm
8
aneurysm wall
8
wall expansion
8
deformable registration
8
maximal rawd
8
manually measured
8

Similar Publications

Purpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions in a singular value decomposition (SVD) subspace. However, the SVD promotes high signal intensity in all tissues, which limits the contrast between tissue types and ultimately reduces the accuracy of registration.

View Article and Find Full Text PDF

Posterior sternoclavicular joint (SCJ) dislocation is a rare but potentially life-threatening injury due to its proximity to critical mediastinal structures. Early diagnosis and prompt management are essential to prevent severe complications such as vascular or respiratory compromise. We report a case of a 23-year-old male who presented to our emergency department five days after a high-energy motor vehicle accident with isolated, closed posterior dislocation of the SCJ.

View Article and Find Full Text PDF

In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.

View Article and Find Full Text PDF

Background: Non-invasive ventilation (NIV) uses positive pressure to assist people with respiratory muscle weakness or severe respiratory compromise to breathe. Most people use this treatment during sleep when breathing is most susceptible to instability. The benefits of using NIV in motor neurone disease (MND) are well-established.

View Article and Find Full Text PDF

Background: The outcome of coronary artery bypass grafting (CABG) depends on several factors, including the quality of the distal anastomoses to the coronary arteries. Early graft failure may be caused by, e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!