Introduction: After surgery for distal femur fractures in elderly patients, weight-bearing is commonly restricted. Immediate non-restrictive weight-bearing might have beneficial effects. There are no randomized studies on the topic. The purpose of this study was to compare the functional outcome between immediate full weight-bearing (FWB) as tolerated and partial weight-bearing (PWB) during the first 8 weeks following plate fixation of distal femur fractures in elderly patients.
Methods: Patients aged 65 years or older with distal femur fractures of AO/OTA types 33 A2, A3, B1, B2, C1, and C2 were included. Exclusion criteria were impaired cognitive function, concomitant injuries, or inability to follow the postoperative regimen. Internal fixation was achieved with an anatomical lateral distal femur plate applied as a strictly bridge-plating construct. The primary outcome measure was the function index of the short musculoskeletal functional assessment (SMFA) after 52 weeks from injury.
Results: Thirty-two patients were randomized to FWB (n = 11) or PWB (n = 21). After 16 and 52 weeks, there were no differences in the mean SMFA function index between FWB and PWB (36 vs 43, = .42 and 52 vs 40, = .18, respectively) nor in the mean EuroQol 5-dimension index or range of motion (ROM). Overall, the SMFA function index was higher at 52 weeks compared with before injury (44 vs 30, = .001) as was the mean bothersome index (37 vs 21, = .011). There was no clear difference in the occurrence of adverse events between the treatment groups.
Conclusions: There were no differences in functional outcome, adverse events, or ROM between immediate FWB and PWB following plate fixation for a distal femur fracture in elderly patients. A distal femur fracture has a negative effect on the functional status of elderly patients that persists at least up to 1 year following injury.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8822340 | PMC |
http://dx.doi.org/10.1177/21514593211055889 | DOI Listing |
Pediatr Radiol
January 2025
Department of Pediatric Genetics, Istanbul University-Cerrahpaşa, Cerrahpasa Medical Faculty, 34098, Cerrahpasa, Istanbul, Turkey.
Background: Heterozygous TRPV4 mutations cause a group of skeletal dysplasias characterized by short stature, short trunk, and skeletal deformities.
Objective: The aim of this study is to compare the natural history of clinical and radiologic features of patients with different TRPV4-related skeletal dysplasias.
Materials And Methods: Thirteen patients with a mutation in TRPV4 were included in the study, and 11 were followed for a median of 6.
J Am Acad Orthop Surg Glob Res Rev
January 2025
From the Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, CT.
Introduction: Venous thromboembolism (VTE) following injury and subsequent fixation of a distal femur fracture (DFFx) is associated with considerable morbidity. However, the incidence of VTE, associated factors, and the relative risk compared with hip fracture (HFx) fixation remains poorly characterized.
Methods: Retrospective cohort study using the PearlDiver M165 database to identify geriatric patients who underwent DFFx and HFx fixation.
Investigating muscle architecture in static and dynamic conditions is essential to understand muscle function and muscle adaptations. Muscle architecture analysis, primarily through extended field-of-view ultrasound imaging, offers high reliability at rest but faces limitations during dynamic conditions. Traditional methods often involve "best fitting" straight lines to track muscle fascicles, leading to possible errors, especially with longer fascicles or those with nonlinear paths.
View Article and Find Full Text PDFJ Spine Surg
December 2024
Surgical and Orthopaedic Research Laboratories, Prince of Wales Clinical School, University of New South Wales, Sydney, AUS.
Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.
Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.
J Clin Orthop Trauma
February 2025
Joints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.
Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!