This study developed an electrocolorimetric extraction technique as a simple, rapid, and green method for the simultaneous preconcentration and determination of Ni(II) in chocolate samples. The system was designed using an agarose gel (3% w/v) solution containing 10% v/v 80 mM dimethylglyoxime (DMG) and 10% v/v 0.03 M ammonia as colorimetric reagents to determine Ni(II) ions. When voltage was applied to the system, Ni(II) ions were extracted from the donor solution into the gel and formed Ni-DMG complexes with a pink color. Under the optimal conditions, a good linear range was obtained from 30 to 750 µg L (R > 0.998) with a detection limit of 1 µg L. Inter- and intra-assay results showing relative standard deviations were less than 2.6% and 1.9%, respectively. Our developed method was applied to determine Ni(II) in chocolate samples. The results were in agreement with those obtained using ICP-OES.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2022.132344 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!