A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of airflow pattern and distance on removal of particulate matters and volatile organic compounds from cigarette smoke using Sansevieria trifasciata botanical biofilter. | LitMetric

Botanical biofilters can effectively remove indoor air pollution. However, to apply botanical biofilters in situ, the distance of botanical biofilter to the pollutants and airflow pattern can be important factors impacting efficiency. This study examined the removal efficiency of particulate matters (PMs) and volatile organic compounds (VOCs) from cigarette smoke, such as formaldehyde and acetone, at various distances (100 cm, 175 cm, 240 cm, and 315 cm) using a Sansevieria trifasciata botanical biofilter. The botanical biofilter was placed inside a testing room (24 m) and exposed to cigarette smoke. The pollutants removal efficiency was evaluated for six cycles (24 h/cycle) and one cycle as a recovery period where botanical biofilter was placed under normal conditions for 30 days. Results showed that the botanical biofilter could remove 140-250 μg m, 147-257 μg m, 212-455 μg m for PM, PM, and PM, respectively, at 8 h. Total VOCs, formaldehyde, and acetone removal were 40%-65%, 46%-69%, and 31%-61% at 24 h. PMs and VOCs removal efficiency can be affected by both distance and pattern of airflow in the testing room. The highest PM and PM elimination appeared at 240 cm and 315 cm, while VOCs removal was high at 100 cm. Botanical biofilter creates airflow vortices around 100 cm, indicating low removal of PMs. This is the first study that demonstrated the effect of airflow patterns on different pollutants removal efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2022.133919DOI Listing

Publication Analysis

Top Keywords

botanical biofilter
28
removal efficiency
16
cigarette smoke
12
botanical
9
airflow pattern
8
removal
8
particulate matters
8
volatile organic
8
organic compounds
8
sansevieria trifasciata
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!