Clinical use of a new frameless optical neuronavigation system for brain biopsies: 10 cases (2013-2020).

J Small Anim Pract

Department for Small Animal, Faculty of Veterinary Medicine, Leipzig University, 04103, Leipzig, Germany.

Published: June 2022

Objectives: The aim of the retrospective study was to describe the brain biopsy procedure using a new frameless optical neuronavigation system and to report diagnostic yield and complications associated with the procedure.

Materials And Methods: The medical records for all dogs with forebrain lesions that underwent brain biopsy with a frameless optical neuronavigation system in a single referral hospital between 2013 and 2020 were retrospectively analysed. Following data were collected: signalment, neurological signs, diagnostic findings, number of brain biopsy samples, sampled region, complications, duration of hospitalisation, whether the samples were diagnostic and histopathological diagnoses. The device consists of a computer workstation with navigation software, an infrared camera, patient tracker and reflective instruments. The biopsy needle was equipped with reflective spheres, so the surgeon could see the position of the needle during sampling the intracranial lesion free handed through a mini-burr hole.

Results: Ten dogs were included. Absolute diagnostic yield based on specific histopathological diagnosis was 73.9%. Three dogs had immune-mediated necrotizing encephalitis, two dogs showed a necrotizing leukoencephalitis and two dogs a meningoencephalitis of unknown origin. In two dogs, the brain specimen showed unspecific changes. In one dog, the samples were non-diagnostic. Seven dogs showed no neurological deterioration, one dog mild temporary ataxia and two dogs died within 36 hours post brain biopsy.

Clinical Significance: In these 10 dogs, the frameless optical neuronavigation system employed was useful to gain diagnostic brain biopsy samples. Considering the mortality rate observed, further studies are needed to confirm the safety of this procedure and prove its actual clinical effectiveness.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jsap.13482DOI Listing

Publication Analysis

Top Keywords

frameless optical
16
optical neuronavigation
16
neuronavigation system
16
brain biopsy
16
dogs
9
diagnostic yield
8
biopsy samples
8
brain
7
biopsy
5
diagnostic
5

Similar Publications

Purpose: Uveal melanoma (UM) represents the most prevalent and aggressive intraocular malignancy in adults. This study examined the outcomes of patients diagnosed with high-risk UM who underwent fractionated stereotactic radiosurgery (fSRS) treatment utilizing a novel LINAC-based frameless technique.

Design: Retrospective, interventional case series.

View Article and Find Full Text PDF

Background: Brain tumor needle biopsy interventions are inflicted with nondiagnostic or biased sampling in up to 25% and hemorrhage, including asymptomatic cases, in up to 60%. To identify diagnostic tissue and sites with increased microcirculation, intraoperative optical techniques have been suggested. The aim of this study was to investigate the clinical implications of in situ optical guidance in frameless navigated tumor biopsies.

View Article and Find Full Text PDF

Background: Brain metastases are the most common intracranial malignancy and remain a substantial source of morbidity and mortality in cancer patients. Linear accelerator based stereotactic radiosurgery (SRS) is widely used and is frequently delivered by hypo-fractionnated volumetric modulated arc therapy using non-coplanar beams, where geometric accuracy and planning margins are a major concern.

Purpose: To give a practical analysis of intrafraction patient motion for multi-target, single isocentre, brain SRS treatments and to derive adapted GTV-to-PTV margins.

View Article and Find Full Text PDF

Objective: Targeting accuracy presents a key factor in achieving maximal safe ablation in laser interstitial thermal therapy (LITT). The VarioGuide system has proven precise for brain biopsies, but data showing its accuracy in combination with LITT are limited. The aim of this study was to determine the phantom and in vivo accuracy of LITT probe placement using the VarioGuide system and to evaluate the effect of targeting error on maximum possible ablation volume.

View Article and Find Full Text PDF
Article Synopsis
  • Radiation treatment has become the preferred option for uveal melanoma, moving away from the more invasive enucleation approach; a new frameless LINAC solution for fractionated stereotactic radiosurgery (fSRS) was developed to preserve the eye.
  • A unique ocular localization box was created featuring adjustable LED lights for patient focus, eye position monitoring with a CCD camera, and tools to track eye movement, ensuring targeted and effective treatment sessions.
  • Initial trials with 10 patients showed that the localization box was effective and well-tolerated, yielding high accuracy for positioning with minimal setup errors, paving the way for future trials to further assess its effectiveness and consistency in various settings.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!