Approximately [Formula: see text] babies are born with only one functioning ventricle and the Fontan is the third and, ideally final staged palliative operation for these patients. This altered circulation is prone to failure with survival rates below [Formula: see text] into adulthood. Chronically elevated inferior vena cava (IVC) pressure is implicated as one cause of the mortality and morbidity in this population. An injection jet shunt (IJS) drawing blood-flow directly from the aortic arch to significantly lower IVC pressure is proposed. A computer-generated 3D model of a 2-4 year old patient with a fenestrated Fontan and a cardiac output of 2.3 L/min was generated. The detailed 3D pulsatile hemodynamics are resolved in a zero-dimensional lumped parameter network tightly-coupled to a 3D computational fluid dynamics model accounting for non-Newtonian blood rheology and resolving turbulence using large eddy simulation. IVC pressure and systemic oxygen saturation were tracked for various IJS-assisted Fontan configurations, altering design parameters such as shunt and fenestration diameters and locations. A baseline "failing" Fontan with a 4 mm fenestration was tuned to have an elevated IVC pressure (+ 17.8 mmHg). Enlargement of the fenestration to 8 mm resulted in a 3 mmHg IVC pressure drop but an unacceptable reduction in systemic oxygen saturation below 80%. Addition of an IJS with a 2 mm nozzle and minor volume load to the ventricle improved the IVC pressure drop to 3.2 mmHg while increasing systemic oxygen saturation above 80%. The salutary effects of the IJS to effectively lower IVC pressure while retaining acceptable levels of oxygen saturation are successfully demonstrated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828777 | PMC |
http://dx.doi.org/10.1038/s41598-022-05985-3 | DOI Listing |
Intern Med
December 2024
Division of Nephrology, Department of Internal Medicine, Showa University Northern Yokohama Hospital, Japan.
In hemodialysis-related portal-systemic encephalopathy (HRPSE), transient negative pressure in the inferior vena cava (IVC) during dialysis increases the blood flow through a portal-systemic shunt, leading to encephalopathy. We report the case of a 74-year-old man with a gastrorenal shunt who developed HRPSE for the first time following venous occlusion due to thrombosis around a right femoral tunneled-cuffed hemodialysis catheter. Before the thrombosis dissolved, ammonia levels increased after dialysis.
View Article and Find Full Text PDFJ Am Soc Echocardiogr
December 2024
Key Laboratory of Ultrasound in Cardiac Electrophysiology and Biomechanics of Sichuan Province, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China. Electronic address:
Background: Exposure to high altitude may unpredictably lead to acute mountain sickness (AMS). The purpose of this study was to identify the predictors of AMS at low altitude by exercise stress echocardiography (ESE).
Methods: A total of 40 healthy adults were enrolled and underwent comprehensive supine bicycle ESE at low altitude, including pulmonary vascular resistance (PVR), right ventricular (RV) area index at the end of diastole (RVEDAi), B-lines, and inferior vena cava (IVC) diameter.
J Emerg Med
August 2024
Department of Emergency Medicine, Oregon Health and Science University, Portland, Oregon. Electronic address:
Background: It is challenging to identify emergency department (ED) patients with sepsis who will require resources such as positive-pressure ventilation, vasopressors, or intensive care unit (ICU) admission.
Objectives: Describe the correlation of cardiopulmonary ultrasound (CPUS) with need for care escalation.
Methods: Single center, prospective, observational study of adult patients with suspected sepsis.
Ultrasound J
November 2024
Faculty of Medicine Ramathibodi Hospital, Mahidol University, 270 Rama VI Rd, Thung Phaya Thai, Ratchathewi, Bangkok, 10400, Thailand.
Background: Venous congestion is associated with adverse cardiovascular outcomes, necessitating accurate venous pressure assessment. Current methods, such as right heart catheterization (RHC), have limitations. Non-invasive techniques, including venous excess ultrasound (VExUS), inferior vena cava (IVC) assessment, and ultrasound-measured jugular venous pressure (uJVP), show promise but require validation in diverse populations.
View Article and Find Full Text PDFInt J Emerg Med
November 2024
Department of Emergency Medicine, Kasturba Medical College, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi, Karnataka, India.
Background: Inferior vena cava (IVC) diameter measurement using ultrasound for volume status assessment has shown satisfactory results and is being adopted in Emergency and critical care settings. IVC diameter can vary depending on the cardiac function, respiratory efforts, intraabdominal pressure, and mechanical ventilation. Due to these factors, IVC measurement cannot be considered a stand-alone technique appropriate for every patient.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!