A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intrathecal Synthesis Index of Specific Anti- IgG: a New Tool for the Diagnosis of Neurosyphilis. | LitMetric

Neurosyphilis (NS) diagnosis is challenging because clinical signs are diverse and unspecific, and a sensitive and specific laboratory test is lacking. We tested the performance of an antibody index (AI) for intrathecal synthesis of specific anti- IgG by enzyme-linked immunosorbent assay (ELISA) for NS diagnosis. We conducted a retroprospective monocentric study including adults with neurological symptoms who had serum and cerebral spinal fluid (CSF) samples collected between 2006 and 2021. Two NS definitions were used. NS1 included patients with neurological symptoms, positive Treponema pallidum particle agglutination (TPPA) serology, and CSF-TPPA of ≥320, as well as CSF-leukocytes of >5 cells/mm and/or CSF-protein of >0.45 g/L and/or a reactive CSF-VDRL/RPR test. NS2 included patients with acute ocular and/or otologic symptoms, positive TPPA serology, and a response to NS treatment. Controls were patients with central nervous system disorders other than neurosyphilis. Anti-Treponema pallidum IgG were measured simultaneously in serum and CSF, and AI was calculated according to Reiber diagram. We assessed the AI test area under the curve (AUC), sensitivity/specificity, and estimated positive and negative predictive values. In total, 16 NS1 patients, 11 NS2 patients, and 71 controls were included. With an AI of ≥1.7 as a positive test for NS diagnostic, specificity was 98.6% (95% confidence interval [CI 95%] of 92.4 to 100.0) and sensitivity was 81.3% (CI 95% of 54.4 to 96.0) for NS1 and 98.6% (CI 95% 92.4 to 100.0) and 27.3% (CI 95% 6.0 to 61.0), respectively, for NS2. Positive and negative predictive values were >95% for NS1 and >85% for NS2, for prevalence above and below 20%. Measuring an AI for intrathecal synthesis of specific anti-Treponema pallidum IgG is a new promising tool highly specific for NS diagnosis. In the context of a lack of a gold standard for the diagnosis of neurosyphilis due to either nonspecific or nonsensitive tests, we present in this article a new promising tool highly specific for NS diagnosis. This new test involves measuring an intrathecal synthesis index of specific anti- IgG by ELISA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8826818PMC
http://dx.doi.org/10.1128/spectrum.01477-21DOI Listing

Publication Analysis

Top Keywords

intrathecal synthesis
16
synthesis specific
16
specific anti-
12
anti- igg
12
diagnosis neurosyphilis
8
neurological symptoms
8
included patients
8
symptoms positive
8
tppa serology
8
anti-treponema pallidum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!