Background: Treating hypoxemia while meeting the soaring demands of oxygen can be a challenge during the COVID-19 pandemic.

Objective: To determine the efficacy of the surgical facemask and the double-trunk mask on top of the low-flow oxygen nasal cannula on arterial partial pressure of oxygen (PaO) in hypoxemic COVID-19 patients.

Design: Randomized controlled trial.

Participants: Hospitalized adults with COVID-19 and hypoxemia treated with the low-flow nasal cannula were enrolled between November 13, 2020, and March 05, 2021.

Interventions: Patients were randomized in a 1:1:1 ratio to receive either the nasal cannula alone (control) or the nasal cannula covered by the surgical facemask or the double-trunk mask. Arterial blood gases were collected at baseline and 30 min after the use of each system. The oxygen output was adapted afterwards to retrieve the baseline pulse oxygen saturation. The final oxygen output value was recorded after another 30-min period.

Main Measures: The primary outcome was the absolute change in PaO. Secondary outcomes included changes in oxygen output, arterial partial pressure of carbon dioxide (PaCO), vital parameters, and breathlessness.

Key Results: Arterial blood samples were successfully collected in 24/27 (8 per group) randomized patients. Compared to the nasal cannula alone, PaO increased with the surgical facemask (mean change: 20 mmHg, 95% CI: 0.7-38.8; P = .04) and with the double-trunk mask (mean change: 40 mmHg; 95% CI: 21-59; P < .001). Oxygen output was reduced when adding the surgical facemask (median reduction: 1.5 L/min [95% CI: 0.5-4.5], P < .001) or the double-trunk mask (median reduction: 3.3 L/min [95% CI: 2-5], P < .001). The double-trunk mask was associated with a PaCO increase of 2.4 mmHg ([95% CI: 0-4.7], P = .049). Neither mask influenced vital parameters or breathlessness.

Conclusions: The addition of the surgical facemask or the double-trunk mask above the nasal cannula improves arterial oxygenation and reduces oxygen consumption.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8971207PMC
http://dx.doi.org/10.1007/s11606-022-07419-2DOI Listing

Publication Analysis

Top Keywords

nasal cannula
28
double-trunk mask
24
surgical facemask
20
oxygen output
16
facemask double-trunk
12
oxygen
10
randomized controlled
8
arterial partial
8
partial pressure
8
arterial blood
8

Similar Publications

Objective: This study aims to quantitatively compare the effects of standard needle irrigation (SNI), passive ultrasonic irrigation (PUI), EDDY, photon-initiated photoacoustic streaming (PIPS), and shock wave-enhanced emission photoacoustic streaming (SWEEPS) on the apical extrusion of irrigation solutions in teeth with severe canal curvature.

Materials And Methods: Seventy-five teeth with a single root and canal, and curvature angles ranging from 20° to 40°, were selected for this study. Root canal curvatures were measured from buccolingual and mesiodistal radiographs using ImageJ software (version 1.

View Article and Find Full Text PDF

Electrolyte imbalance management is crucial in diverse clinical scenarios, with intravenous potassium repletion often required. High-concentration infusions can pose severe complications if extravasation occurs, leading to phlebitis, local tissue damage, or in severe cases, cutaneous necrosis. This risk is elevated in geriatric patients due to factors like reduced tissue elasticity and sensitivity.

View Article and Find Full Text PDF

Background: High-flow nasal cannula (HFNC) and non-invasive ventilation (NIV) are commonly used for respiratory support. This study aims to first establish whether to use HFNC or NIV based on comfort levels, and subsequently evaluate diaphragmatic function under equivalent comfort levels to determine the optimal modality for clinical application.

Methods: A self-controlled, non-randomized study was conducted with 10 healthy respiratory physicians as participants.

View Article and Find Full Text PDF

Background: Iatrogenic cervical kyphosis (ICK) often requires complex anterior and posterior correction, which is associated with multiple complications. Consequently, there is a need to investigate alternative treatment approaches that streamline the operative process and markedly diminish postoperative complications. This study, therefore, aimed to evaluate the feasibility and efficacy of a single-stage anterior controllable antedisplacement fusion (ACAF) in revision surgeries for ICK.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!