Due to ligament laxity, bearing dislocation occurs in 1-6% of Oxford Domed Lateral (ODL) replacements with most dislocations occurring medially. Dislocations were studied using a previously built mechanical rig, however testing using the rig was inefficient. The aim of this study was to develop a better tool that was more reliable and efficient. An established robotics software package, the Open Motion Planning Library, was modified to accept the ODL components. Using a robotics path planning algorithm, the mobile bearing was allowed to find a way out from between the femoral and tibial components i.e. to dislocate. Testing assessed a range of clinically relevant positions of the femoral component relative to the tibial component. Dislocations were labelled as medial, lateral, anterior or posterior depending on the dislocation direction. The Distraction to Dislocation (DD) measured the minimum vertical distraction of the femoral component from the tibial component for a dislocation to occur. Results were validated against the mechanical rig. Statistical analysis of medial dislocation showed excellent agreement with an intraclass correlation value of 0.993 (95% CI 0.982-0.998). All DDs from the dislocation analysis tool were within 1 mm of the mechanical rig DDs with results sharing a remarkably similar trend. The robotics dislocation analysis tool output DDs which were marginally higher than the manual mechanical rig: 0.50 mm anteriorly, 0.25 mm posteriorly and 0.50 mm laterally. Medially, the computational DD differed on average by 0.09 mm (stand deviation: 0.2026 mm). Our study describes the development and validation of a novel robotics dislocation analysis tool, which allows mobile bearing dislocation risk quantification. The tool may also be used to improve surgical implantation parameters and to assess new implant designs that aim to reduce the medial dislocation risk to an acceptable level.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8825833PMC
http://dx.doi.org/10.1038/s41598-022-05938-wDOI Listing

Publication Analysis

Top Keywords

mechanical rig
16
mobile bearing
12
bearing dislocation
12
dislocation analysis
12
analysis tool
12
dislocation
11
robotics path
8
path planning
8
planning algorithm
8
femoral component
8

Similar Publications

Unveiling the impact of pipe materials on water hammer in pressure pipelines: an experimental and numerical study.

Sci Rep

December 2024

Department of Mechanical Design, Faculty of Engineering, Helwan University, P.O. Box 11718, Mataria, Helmeiat-Elzaton, Cairo, Egypt.

Water hammer (WH) is a phenomenon characterized by the rapid opening or closing of valves or pumps in pipelines, resulting in a disruptive noise, intense vibrations, and potential damage to pipes, fittings, structures, and even human safety. While WH arresters are commonly employed to mitigate this issue in smaller plumbing systems, alternative solutions are required for larger applications like power plants. Researchers have proposed the utilization of pipe materials with a low modulus of elasticity in areas prone to WH events, as these materials possess the capability to absorb a significant portion of the resulting vibrations.

View Article and Find Full Text PDF

Comparing patellofemoral kinematics assessed with a novel Muscle Actuator System and an Oxford Rig using non-cadaveric knees.

J Biomech Eng

December 2024

Biomechanical Engineering Research Laboratory, Department of Mechanical and Materials Engineering, Western University, 1151 Richmond St, London, ON, N6A 3K7, Canada.

Total knee replacement (TKR) failure, low patient satisfaction and high revision surgery rates may stem from insufficient pre-clinical testing. Conventional joint motion simulators for pre-clinical testing of TKR implants manipulate a knee joint in force, displacement, or simulated muscle control. However, a rig capable of using all three control modes has yet to be described in literature.

View Article and Find Full Text PDF

This study is focused on optimizing electromagnetic acoustic transducer (EMAT) sensors for enhanced ultrasonic guided wave signal generation in steel cables using CAD and modern manufacturing to enable contactless ultrasonic signal transmission and reception. A lab test rig with advanced measurement and data processing was set up to test the sensors' ability to detect cable damage, like wire breaks and abrasion, while also examining the effect of potential disruptors such as rope soiling. Machine learning algorithms were applied to improve the damage detection accuracy, leading to significant advancements in magnetostrictive measurement methods and providing a new standard for future development in this area.

View Article and Find Full Text PDF

The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty.

J Clin Med

November 2024

Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, 81377 Munich, Germany.

: Anterior knee pain is a prevalent issue post total knee arthroplasty, often necessitating revision surgery. Various factors contribute to this complication, including patellar maltracking and excessive patellofemoral load. Kinematic alignment has emerged as an alternative, showing promising outcomes in clinical studies.

View Article and Find Full Text PDF

In this paper, the fatigue resistance of a full-scale Steel Catenary Riser (SCR) girth weld is investigated using the Strength-Number of cycles (-) curve method based on weld formation quality and fracture mechanics approaches. The test results, presented in the form of - curves, are superior to the design curve E in BS 7608. Compared with the - curve determined by a resonant bending rig, the analytical fracture mechanics, i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?