Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate safety and efficacy of a custom-manufactured artificial iris device (CustomFlex Artificial Iris; HumanOptics AG) for the treatment of congenital and acquired iris defects.
Design: Multicenter, prospective, unmasked, nonrandomized, interventional clinical trial.
Participants: Patients with photophobia, sensitivity secondary to partial or complete congenital or acquired iris defects, or both.
Methods: Eyes were implanted from November 26, 2013, to December 1, 2017, with a custom, foldable artificial iris by 1 of 4 different surgical techniques. Patients were evaluated 1 day, 1 week, and 1, 3, 6, and 12 months after surgery. At each examination, slit-lamp findings, intraocular pressure, implant position, subjective visual symptoms, and complications were recorded. Corrected distance visual acuity (CDVA) and endothelial cell density (ECD) were measured at 3, 6, or 12 months as additional safety evaluations. The 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was used to assess health-related quality of life affected by vision. The Global Aesthetic Improvement Scale was used to assess cosmetic results.
Main Outcome Measures: Photosensitivity, glare, visual symptoms, NEI VFQ-25 score, Global Aesthetic Improvement Scale rating, prosthesis-related adverse events, intraocular lens (IOL)-related adverse events, and surgery-related adverse events 12 months after surgery.
Results: At the 12-month postoperative examination, a 59.7% reduction in marked to severe daytime light sensitivity (P < 0.0001), a 41.5% reduction in marked to severe nighttime light sensitivity (P < 0.0001), a 53.1% reduction in marked to severe daytime glare (P < 0.0001), and a 48.5% reduction in severe nighttime glare (P < 0.0001) were found. A 15.4-point improvement (P < 0.0001) in the NEI VFQ-25 total score was found, and 93.8% of patients reported an improvement in cosmesis as measured by the Global Aesthetic Improvement Scale 12 months after surgery. No loss of CDVA of > 2 lines related to the device was found. Median ECD loss was 5.3% at 6 months after surgery and 7.2% at 12 months after surgery.
Conclusions: The artificial iris surpassed all key safety end points for adverse events related to the device, IOL, or implant surgery and met all key efficacy end points, including decreased light and glare sensitivity, improved health-related quality of life, and satisfaction with cosmesis. The device is safe and effective for the treatment of symptoms and an unacceptable cosmetic appearance created by congenital or acquired iris defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ophtha.2022.01.029 | DOI Listing |