Typical doses and typical values for fluoroscopic diagnostic and interventional procedures.

J Radiol Prot

Medical Faculty, Department of Diagnostic and Institutional Radiology, University Dusseldorf, D-40225 Dusseldorf, Germany.

Published: March 2022

To implement typical doses (TD) and typical values (TV) for fluoroscopic diagnostic and interventional procedures. A total of 3811 fluoroscopic procedures performed within 34 months on three devices were included in this retrospective study. Dose-, patient- and procedure-related information were extracted using the institutional dose management system (DMS). TD/TV were defined as median dose and calculated for the five most frequent procedures per device for dose area product (DAP), cumulative air kerma (CAK) and fluoroscopy time (FT). National diagnostic reference levels and other single facility studies were compared to our results. Additionally, the five procedures with the highest doses of each device were analysed. To evaluate the data coverage of the DMS compared to the picture archiving and communication system (PACS), procedure lists were extracted from the PACS and compared to the procedure information extracted from the DMS. TD/TV for 15 procedures were implemented. Among all devices, TD for DAP ranged between 0.6 Gycmfor port catheter control (= 64) and 145.9 Gycmfor transarterial chemoembolisation (= 84). TD for CAK ranged between 5 mGy for port catheter control and 1397 mGy for aneurysm treatment (= 129) and TV for FT ranged between 0.3 min for upper cavography (= 67) and 51.4 min for aneurysm treatment. TD for DAP and CAK were lower or within the range of other single facility studies. The five procedures with the highest median DAP per device were identified, 6 of 15 procedures were also found to be among the most frequent procedures. Data coverage of the DMS compared to the PACS ranged between 71% (device 2, stroke treatment) and 78% (device 1, lower limb angiography) for the most common procedure per device. Thus, in 22%-29% of cases dose data of the performed procedure was not transferred into the DMS. We implemented TD/TV for fluoroscopic diagnostic and interventional procedures which enable a comprehensive dose analysis and comparison with previously published values.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/ac5294DOI Listing

Publication Analysis

Top Keywords

fluoroscopic diagnostic
12
diagnostic interventional
12
interventional procedures
12
procedures
10
typical doses
8
doses typical
8
typical values
8
values fluoroscopic
8
dms td/tv
8
frequent procedures
8

Similar Publications

Context: To further improve rehabilitation programs while preventing overstretching the anterior cruciate ligament (ACL), a thorough understanding of the knee kinematics and ACL length change during closed kinetic chain and open kinetic chain (OKC) exercises is essential. The measurement of ACL graft length relates to the changes in strain experienced by the ACL graft during different types of exercises rather than simple physical length.

Objective: This study aimed to determine the effects of closed kinetic chain and OKC exercises on tibiofemoral kinematics and ACL graft length changes following double-bundle ACL reconstruction.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

BACKGROUND Swallowing is a complex behavior involving the musculoskeletal system and higher-order brain functions. We investigated the effects of different modalities of repetitive transcranial magnetic stimulation (rTMS) on the unaffected hemisphere and observed correlation between suprahyoid muscle activity and cortical activation in unilateral stroke patients when swallowing saliva, based on functional near-infrared spectroscopy (fNIRS). MATERIAL AND METHODS From November 2022 to March 2023, twenty-five patients with unilateral stroke were screened using computed tomography or magnetic resonance imaging and identified via a video fluoroscopic swallow study.

View Article and Find Full Text PDF

Background: Femoroacetabular impingement (FAI) is a well-recognized cause of hip pain in adults. The hip-spine relationship between the femur, pelvis, and lumbosacral spine has garnered recent attention in hip arthroplasty. However, the hip-spine relationship has not been well described in patients with FAI.

View Article and Find Full Text PDF

Attempted ablation of an orbital cyst in a dog with 1% polidocanol using fluoroscopy and contrast cystography.

Vet Ophthalmol

January 2025

Cardiology & Cardiac Surgery, Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA.

A 4-year-old female spayed mixed-breed dog received enucleation surgery of the right eye in 2018 following the diagnosis of glaucoma. The patient was presented in 2021 for recurrent swelling of the right orbit. Ultrasound confirmed the presence of a cystic structure, and chemical ablation with 1% polidocanol (compounded, Stokes Pharmacy, Mt.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!