Effect of the Molecular Structure Change of a Matrix Polymer (Nylon 6) on the Deformation of Dispersed Phase (a Thermotropic Liquid Crystalline Polymer) Droplets in Shear Flow.

ACS Omega

RIAM, Department of Materials Science and Engineering, College of Engineering, Seoul National University, Kwanakro 1, Kwanakku, Seoul 08826, Korea.

Published: February 2022

In this work, we investigated the effect of a change in the molecular structure and ensuing molar mass change of a matrix polymer (polyamide 6, Ny 6) on droplet deformation of a dispersed thermotropic liquid crystalline polymer (TLCP, a poly(ester amide)) in shear flow. This study focuses on a total capillary number (the sum of the shear capillary number and the elasticity capillary number) and the viscosity ratio between the TLCP and Ny 6, for the morphological development and mechanical performance of TLCP/Ny 6 blends. In contrast to Ny 6, which has a lower melt viscosity than the TLCP melt, a modified Ny 6 (m-Ny 6) with . 2 orders higher melt viscosity than that of Ny 6 at a shear rate of 1 s was found to facilitate the deformation of the TLCP phase. A total capillary number was defined to characterize the viscoelasticity effect on droplet deformation in the blend system. The first normal stress difference obtained from the viscosity curve using Steller's method was used for the evaluation of the elasticity capillary number. The total capillary number for the Ny 6 blend was far less than the critical capillary number and was insufficient for the dispersed TLCP droplets to be deformed. The shear capillary number of the m-Ny 6 blend was greater than the critical capillary number but was still insufficient for droplet deformation into fibril shapes. The total capillary number, including the elastic capillary number, was sufficiently greater than the critical capillary number for deformation of the dispersed TLCP droplets. Morphological observations and a comparison with the theoretical work confirmed the importance of the viscoelasticity of the melt in the immiscible Ny 6/TLCP blends for composite fabrication in shear flow. Both the high viscosity and the first normal stress difference of m-Ny 6 promote the deformation and fibrillation of the dispersed TLCP droplets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8811891PMC
http://dx.doi.org/10.1021/acsomega.1c05497DOI Listing

Publication Analysis

Top Keywords

capillary number
48
total capillary
16
deformation dispersed
12
shear flow
12
droplet deformation
12
capillary
12
number
12
critical capillary
12
dispersed tlcp
12
tlcp droplets
12

Similar Publications

Droplet coalescence in microchannels is a complex phenomenon influenced by various parameters such as droplet size, velocity, liquid surface tension, and droplet-droplet spacing. In this study, we thoroughly investigate the impact of these control parameters on droplet coalescence dynamics within a sudden expansion microchannel using two distinct numerical methods. Initially, we employ the boundary element method to solve the Brinkman integral equation, providing detailed insights into the underlying physics of droplet coalescence.

View Article and Find Full Text PDF

Cell-free DNA release following psychosocial and physical stress in women and men.

Transl Psychiatry

January 2025

Department of Genetic Psychology, Faculty of Psychology, Ruhr-University Bochum, Universitätsstraße 150, Bochum, Germany.

Cell-free DNA (cfDNA) is continuously shed by all cells in the body, but the regulation of this process and its physiological functions are still largely unknown. Previous research has demonstrated that both nuclear (cf-nDNA) and mitochondrial (cf-mtDNA) cfDNA levels increase in plasma in response to acute psychosocial and physical stress in males. This study further investigated these findings by testing 31 female participants (16 using oral hormonal contraception and 15 not using oral hormonal contraception), and the results were subsequently compared with those of 16 male participants.

View Article and Find Full Text PDF

A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves.

Sensors (Basel)

January 2025

Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.

(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.

View Article and Find Full Text PDF

Background: Cardiac aging is associated with myocardial remodeling and reduced angiogenesis. Counteracting these changes with natural products is a preventive strategy with great potential. The aim of this study was to evaluate the effect of fruit juice (AMJ) supplementation on age-related myocardial remodeling in aged rat hearts.

View Article and Find Full Text PDF

Accurate models for predicting drop dynamics, such as maximum drop departure sizes, are crucial for estimating heat transfer rates during condensation on superhydrophobic (SH) surfaces. Previous studies have focused on examining the heat transfer rates for SH surfaces under the influence of gravity or vapor flowing over the surface. This study investigates the impact of surface solid fraction and texture scale on drop mobility in a condensing environment with a humid air flow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!