Biomechanical testing is a necessity given the development of novel implants used in the osteosynthesis of hip fractures. The purpose of biomechanical testing is to recreate realistic conditions similar to the conditions. Although biomechanical testing of hip arthroplasty has been standardized since the 1970s, there is no consensus at present on testing methodology for osteosynthesis of hip fractures. Most biomechanical studies examining the fractures of the proximal femur in order to optimize implants opt for loading the bone-implant ensemble directly on the femoral head or using a metallic loading part. This loading technique fails to perform a mechanical stress distribution similar to conditions, which could alter the outcome. The present study aimed to design loading/unloading cups with mechanical properties that resemble those of the cartilage at the hip level. Through the impression and scanning of the cast models obtained, a digital 3D model was created in STL format and this was processed in order to obtain the computer numerical control (CNC) trajectories of the printing head. For prototyping using additive manufacturing technology, a thermoplastic polymer with biochemical properties, such as tensile strength, that resemble those of the adult hip and a Stratasys FORTUS 250 mc CNC machine were used. Loading/unloading cups with similar anatomy and biomechanical forces compared with those of the adult hip were created, which allowed the experimental simulation of the conditions during walking.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8794553PMC
http://dx.doi.org/10.3892/etm.2022.11125DOI Listing

Publication Analysis

Top Keywords

biomechanical testing
12
biomechanical studies
8
proximal femur
8
osteosynthesis hip
8
hip fractures
8
loading/unloading cups
8
adult hip
8
biomechanical
6
hip
6
original method
4

Similar Publications

The shoulder joint complex is prone to musculoskeletal issues, such as rotator cuff-related pain, which affect two-thirds of adults and often result in suboptimal treatment outcomes. Current musculoskeletal models used to understand shoulder biomechanics are limited by challenges in personalization, inaccuracies in predicting joint and muscle loads, and an inability to simulate anatomically accurate motions. To address these deficiencies, we developed a novel, personalized modeling framework capable of calibrating subject-specific joint centers and functional axes for the shoulder complex.

View Article and Find Full Text PDF

Bioinspired surface structures for added shear stabilization in suction discs.

Sci Rep

January 2025

John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, 02134, USA.

Many aquatic organisms utilize suction-based organs to adhere to diverse substrates in unpredictable environments. For multiple fish species, these adhesive discs include a softer disc margin consisting of surface structures called papillae, which stabilize and seal on variable substrates. The size, arrangement, and density of these papillae are quite diverse among different species, generating complex disc patterns produced by these structures.

View Article and Find Full Text PDF

The incidence of head impacts in rugby has been a growing concern for player safety. While rugby headgear shows potential to mitigate head impact intensity during laboratory simulations, evaluating its on-field effectiveness is challenging. Current rugby-specific laboratory testing methods may not represent on-field conditions.

View Article and Find Full Text PDF

Background: A lateral extra-articular tenodesis (LET) is increasingly being utilized to augment an anterior cruciate ligament reconstruction because it has been shown to reduce the risk of postreconstruction graft failure or recurrent rotatory instability. Various femoral fixation techniques are available, including the use of an interference screw, staple, or suture anchor.

Purpose: To determine and compare the biomechanical properties of an LET graft when using an interference screw, staple, or suture anchor for the femoral fixation for a modified Lemaire LET.

View Article and Find Full Text PDF

Purpose: This biomechanical study aimed to investigate the effectiveness of a hinged elbow orthosis in reducing passive valgus forces following medial ulnar collateral ligament (UCL) injuries of the elbow joint. The hypothesis tested was that a hinged elbow orthosis reduces these passive valgus forces.

Methods: Eight fresh frozen cadaveric elbow specimens were prepared and tested under three scenarios: intact ligaments, simulated UCL rupture and application of a hinged elbow brace after simulated UCL rupture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!