A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preliminary outcomes of the LifeStream balloon-expandable stentgraft in Zenith Iliac branch device to preserve pelvic circulation: A Korean multicenter study. | LitMetric

Background: To evaluate early outcomes of aortoiliac or isolated iliac artery aneurysm repair using the Zenith® Bifurcated Iliac Side (ZBIS) stent graft combined with the LifeStream™ Balloon Expandable Vascular Covered Stent as a bridging stentgraft.

Methods: Between August 2018 and February 2020, 38 patients (37 male, mean age 72.7 years) received 46 LifeStream stents in conjunction with 38 ZBIS stent grafts to bridge hypogastric arteries for aneurysm repair in six university hospitals in Korea. The primary outcomes were technical success rate and procedure-related complications. Secondary outcomes were bridging stent graft patency and re-intervention.

Results: All procedures were performed as elective standard endovascular aortic aneurysm repair (EVAR) and unilateral iliac branch device (IBD). Mean follow-up was 13.1 months, and patient overall survival rate was 96.7%. Technical success rate was 76.3% (n = 29). Causes of failure included seven total endoleaks; six type Ic and one type IIIc from the IBD junction, one unintentional IIA coverage, and one failure to deploy the IIA stent graft. Procedure-related complications occurred in two patients: one LifeStream migration and one ZBIS stent graft migration. Overall patency rates for the LifeStream and ZBIS stents were 97.4% and 97.2%, respectively.

Conclusion: This multicenter preliminary experience with the LifeStream™ Balloon Expandable Vascular Covered Stent in IBD demonstrated good patency; however, an unexpectedly high rate of type Ic endoleaks was observed. Combined use of the LifeStream stent with the ZBIS stent graft is safe and feasible to preserve pelvic circulation with good patency and a low rate of device-related reintervention.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.asjsur.2022.01.012DOI Listing

Publication Analysis

Top Keywords

stent graft
20
zbis stent
16
aneurysm repair
12
stent
9
iliac branch
8
branch device
8
preserve pelvic
8
pelvic circulation
8
lifestream™ balloon
8
balloon expandable
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!