Introduction: To assess the 1-year outcomes of vertically fixated posterior chamber phakic intraocular lens implantation through a superior corneal incision.
Methods: This pilot study comprised 78 eyes of 53 consecutive patients undergoing vertically fixated implantable collamer lens (ICL) implantation through a superior corneal incision to correct moderate to high myopia and myopic astigmatism. We prospectively determined the safety, efficacy, predictability, stability, and adverse events preoperatively, and at 1 week and 1, 3, and 12 months postoperatively.
Results: The mean follow-up period was 10.4 ± 5.4 months. Uncorrected and corrected visual acuity were -0.20 ± 0.10 and -0.25 ± 0.07 logMAR, respectively, at 1 year postoperatively. At 1 year postoperatively, 98% and 100% of eyes were within 0.5 and 1.0 D, respectively, of the targeted correction. A nonsignificant change in manifest refraction of -0.01 ± 0.08 D occurred from 1 week to 1 year. The manifest astigmatism decreased significantly, from 0.69 ± 0.73 D preoperatively to 0.21 ± 0.27 D at 1 year postoperatively (Mann-Whitney U test, p < 0.001). No vision-threatening complications occurred at any time in this series.
Conclusions: According to our experience, the vertically fixated ICL through a superior incision achieved good results, without significant complications. Considering that younger patients requiring ICL surgery tend to have with-the-rule astigmatism, this surgical technique may be a viable option for reducing astigmatism without using toric ICLs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8927518 | PMC |
http://dx.doi.org/10.1007/s40123-022-00470-6 | DOI Listing |
The primary aim of this descriptive cross-sectional study was to examine the relationship between ocular motility and motor skills in school-age children. Participants included 142 schoolchildren (mean age: 7.08 ± 0.
View Article and Find Full Text PDFPLoS One
January 2025
Division of Kinesiology and Health, University of Wyoming, Laramie, WY, United States of America.
The inversion effect in biological motion suggests that presenting a point-light display (PLD) in an inverted orientation impairs the observer's ability to perceive the movement, likely due to the observer's unfamiliarity with the dynamic characteristics of inverted motion. Vertical dancers (VDs), accustomed to performing and perceiving others to perform dance movements in an inverted orientation while being suspended in the air, offer a unique perspective on this phenomenon. A previous study showed that VDs were more sensitive to the artificial inversion of PLDs depicting dance movements when compared to typical and non-dancers if given sufficient dynamic information.
View Article and Find Full Text PDFJ Am Podiatr Med Assoc
January 2025
‡Canakkale Onsekiz Mart University Medical Faculty, Department of Orthopedics and Traumatology, Çanakkale, Turkey.
Background: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires.
Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material.
Acta Orthop Traumatol Turc
December 2024
Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Ataturk Training and Research Hospital, Izmir, Türkiye.
Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.
Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.
Aim: Fixed retention is the method of choice for permanent stabilization of the treatment outcome. In recent years, CAD/CAM techniques have been developed to produce retainers with high precision and tension-free fit. The aim of this retrospective study was to evaluate the suitability of a semi-industrial retainer manufacturing process (office-based construction, external laboratory manufacturing) in terms of positioning accuracy and post-treatment changes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!