Introduction: The prevalence of obesity is increasing. However, data on the periprocedural complication rate of catheter ablation for arrhythmia in patients stratified by body mass index (BMI) are scarce.
Methods: This study included 1000 consecutive patients (age 62.0 ± 14.4 years) undergoing catheter ablation for cardiac arrhythmia. The primary study endpoint was any periprocedural major complication (cardiac tamponade, pseudoaneurysm, arteriovenous fistula, transient ischemic attack, stroke, valve damage, myocardial infarction, or death).
Results: The mean BMI was 27.6 ± 5.1 kg/m and the majority of patients were overweight (BMI 25.0-29.9 kg/m , 43.4%). A BMI of 30.0-34.9 kg/m (Class I obesity) was present in 177 (17.7%) of patients, a BMI of 35.0-39.9 kg/m (Class II obesity) in 67 (6.7%), and a BMI ≥ 40 kg/m (Class III obesity) in 16 (1.6%). There were 31 major complications (3.1%) and one fatality (0.1%) due to terminal heart failure in a patient undergoing palliative ventricular tachycardia ablation. There was no significant impact of the BMI on the rate of major complications (p = .495). Compared to normal weight patients, odds ratios for complications in overweight patients, as well as Class I, II, and III obesity were 1.1 (95% confidence interval (CI): 0.8, 1.7), 1.3 (CI: 0.6, 2.6), 1.4 (CI: 0.5, 4.1), and 1.6 (CI: 0.4, 6.3), respectively. Radiation exposure and procedure duration were significantly increased in obese patients (p < .001 and p = .001, respectively).
Conclusion: In this study, obesity did not have a significant impact on the incidence of periprocedural complications after CA for cardiac arrhythmia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.15400 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.
Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.
Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.
J Cardiovasc Electrophysiol
January 2025
Sakakibara Kinen Byoin, Fuchu, Japan.
Introduction: Freedom from recurrences of atrial tachyarrhythmia (ATA) is suboptimal after pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (PsAF). This sub-analysis from the Cryo Global Registry sought to investigate predictors of ablation success after PVI using cryoballoon ablation (CBA) for PsAF.
Methods And Results: ATA recurrence was defined as ≥ 30 s recurrence of atrial fibrillation, atrial flutter or atrial tachycardia after a 90-day blanking period and through 12-months.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!