The objective of this study was to evaluate the relationship between random capillary glucose levels in healthy pregnant women and infant size at birth and childhood growth to the age of five years. This population-based cohort study comprised 10,937 healthy mother-child dyads. Data on highest maternal random capillary glucose level during pregnancy and sequential anthropometric data on their children during the first five years of life were gathered from the Uppsala County Mother and Child Cohort. Statistical analyses were performed with linear regression and linear mixed effect regression models. We found that higher glucose level during pregnancy was associated with higher weight z-score (β 0.10, 95% confidence interval (CI) 0.08-0.11), length z-score (β 0.05, 95% CI 0.03-0.07) and BMI z-score (β 0.09, 95% CI 0.07-0.12) at birth, adjusted for maternal BMI and country of birth, smoking during pregnancy and parity. The association did not remain at 1½, 3, 4 and 5 years of age. There was a positive relationship between higher glucose level during pregnancy and a decrease in weight z-score, height z-score and BMI z-score from birth to 5 years of age. In conclusion, higher random capillary glucose levels in pregnant healthy women were associated with greater infant size at birth, as well as decreased growth velocity in early childhood.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8813989PMC
http://dx.doi.org/10.1038/s41598-022-05821-8DOI Listing

Publication Analysis

Top Keywords

capillary glucose
16
random capillary
12
glucose level
12
level pregnancy
12
childhood growth
8
growth age
8
cohort study
8
glucose levels
8
infant size
8
size birth
8

Similar Publications

A dysregulated metabolism has been studied as a key aspect of the COVID-19 pathophysiology, but its longitudinal progression in severe cases remains unclear. In this study, we aimed to investigate metabolic dysregulation over time in patients with severe COVID-19 requiring mechanical ventilation (MV). In this single-center, prospective, observational study, we obtained 236 serum samples from 118 adult patients on MV in an ICU.

View Article and Find Full Text PDF

All-Printed Microfluidic-Electrochemical Devices for Glucose Detection.

Biosensors (Basel)

November 2024

Engineering Physics, McMaster University, Hamilton, ON L8S 4L8, Canada.

Free-standing capillary microfluidic channels were directly printed over printed electrodes using a particle/polymer mixture to fabricate microfluidic-electrochemical devices on polyethylene terephthalate (PET) films. Printed devices with no electrode modification were demonstrated to have the lowest limit of detection (LOD) of 7 μM for sensing glucose. The study shows that both a low polymer concentration in the mixture for printing the microfluidic channels and surface modification of the printed microfluidic channels using 3-aminopropyltrimethoxysilane can substantially boost the device's performance.

View Article and Find Full Text PDF

This study aims to explore the potential of using resveratrol (RES) to treat diabetic retinopathy (DR), as well as the involved molecular mechanisms underlying RES-mediated protection against DR. High concentration of glucose (HG)-induced Human retinal capillary endothelial cells (HRCECs) cell model and streptozotocin (STZ)-induced DR mice model were established. Then, cell viability, apoptosis, reactive oxygen species (ROS) levels, pro-inflammatory factors, and expression of the related proteins SIRT1, HMGB1, VEGF, and CD31 were assayed by a series of cell biology methods.

View Article and Find Full Text PDF

Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners.

Int J Sports Physiol Perform

December 2024

Division of Health, Engineering, Computing and Science, Te Huataki Waiora School of Health, University of Waikato, Tauranga, New Zealand.

Purpose: Continuous-glucose-monitoring (CGM) sensors provide near-real-time glucose data and have been introduced commercially as a tool to inform nutrition decisions. The aim of this pilot study was to explore how factors such as the menstrual phase, extended running duration, and carbohydrates affect CGM outcomes among trained eumenorrheic females in an outdoor simulated ultraendurance running event.

Methods: Twelve experienced female ultrarunners (age 39 [6] y) participated in this crossover study.

View Article and Find Full Text PDF

Objectives: To describe a variant hemoglobin that interferes with HbA analysis by cation exchange HPLC.

Case Presentation: A 78 years-old Spanish male patient visited the Internal Medicine Clinic for a routine check-up, with HbA included to screen for diabetes. He had suffered hypertension and dyslipidemia, and the patient had no previous symptoms suggestive of diabetes such as hyperglycemia, weight loss, polydipsia, polyuria or tiredness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!