Introduction: No entirely reliable method to assess union during Ilizarov treatment exists. Premature frame removal results in treatment failure, and alternative methods of assessment warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight-bearing, indicating progress towards union. A previous study from our group demonstrated this approach may be clinically applicable. We investigated translation of this method into clinical practice in an observational pilot study.
Materials And Methods: Patients with tibial shaft fractures treated with Ilizarov frames were recruited. A prototype depth gauge was used to measure wire deflection on weight-bearing. Investigators undertaking the measurement were blinded to the clinical stage of treatment, and clinicians caring for the patient were blinded to deflection results. Patient records were reviewed at the end of treatment to determine likely fracture stability at each time point. Deflection per kg of weight applied, per mm from the ring was compared between stable and unstable situations.
Results: Thirty-one measurements were obtained in 14 patients. The situation was deemed stable at 13 and unstable at 18 measurements. The median deflection in the stable group was 0.030 microns/kg/mm (IQR 0.005-0.104) and 0.165 microns/kg/mm (IQR 0.072-0.328) in the unstable group. This difference was statistically significant (Wilcoxon Mann-Whitney test = 0.0014). ROC curve analysis revealed that wire deflection was able to predict clinical stability (AUC 0.84, <0.0001). Various technical problems were encountered when using the device which would potentially limit its clinical utility in its current form.
Conclusion: In this set of observations, wire deflection was significantly associated with clinically and radiologically determined stability. Though various practical limitations were encountered in using the prototype measurement device, this proof-of-concept study supports further development of this approach. The research group plan to develop a smaller, more reliable device for further clinical testing in a larger group of patients.
How To Cite This Article: Lineham B, Stewart T, Ward J, Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study. Strategies Trauma Limb Reconstr 2021;16(3):132-137.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778728 | PMC |
http://dx.doi.org/10.5005/jp-journals-10080-1537 | DOI Listing |
Sci Rep
January 2025
Institute of the Malay World and Civilisation (ATMA), Universiti Kebangsaan Malaysia (UKM), 43600, Bangi, Selangor, Malaysia.
The adoption of pultruded glass fibre-reinforced polymer (pGFRP) composites as a substitute for traditional wooden cross-arms in high transmission towers represents a relatively novel approach. These materials were selected for their high strength-to-weight ratio and lightweight properties. Despite various studies focusing on structures improvement, there still have a significant gap in understanding the deformation characteristics of full-scale cross-arms under actual operational loads.
View Article and Find Full Text PDFJ Endourol
December 2024
Department of Urology, Jiangxi Provincial Key Laboratory of Urinary System Diseases, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
Encrustation significantly affects the lifespan of Allium stents. Currently, there is no established treatment for Allium ureteral stent encrustation. This study introduces a method for treating these encrustations using a flexible ureteroscopy (F-URS) combined with a novel ultra-flexible ureteral access sheath (UF-UAS).
View Article and Find Full Text PDFDiscov Appl Sci
November 2024
Industrial Systems Engineering, Faculty of Engineering and Applied Science, University of Regina, 3737 Wascana Pkwy, Regina, SK S4S Canada.
Sci Rep
October 2024
Xi'an Keyuan Municipal Engineering Consulting Co, Xi an, 710000, China.
Int J Dent
October 2024
Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
An innovative retention protocol was developed to create a new 3D-printed fixed retainer employing SprintRay OnX nanoceramic hybrid resin. The feasibility and usability of the retainer were subsequently evaluated. Identification and characterization of SprintRay OnX was done using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy with energy dispersive X-ray (SEM-EDX), field emission scanning electron microscope (FE-SEM), X-ray diffraction (XRD), and flexural strength.