The free electrons inside precious metals such as Au vibrate when the surface of the metal is irradiated with an electromagnetic wave of an appropriate frequency. This oscillation is referred to as surface plasmon resonance (SPR), and the resonance frequency varies with permittivity of the medium around the metal. SPR sensors are widely applied in the fields of bioscience and pharmaceutical sciences, including biosensing for drug discovery, biomarker screening, virus detection, and testing for food safety. Here, we fabricated a metal-insulator-metal (MIM) SPR sensor by constructing two-dimensional (2D) regular array of Au colloidal particles (2D colloidal crystals) on an insulator layer over a thin Au film coated on a glass substrate surface. The 2D crystals were fabricated by electrostatically adsorbing negatively charged three-dimensional crystals onto a positively charged thin insulator formed on Au film. The plasmon peaks/dips from the MIM structure were measured in aqueous solutions of ethylene glycol (EG) at various concentrations. Multiple plasmon peaks/dips were observed due to the localized SPR (LSPR) of the Au particles and the Fano resonance between the Au particles and thin film. The plasmon peaks/dips shifted to higher wavelengths on increasing EG concentrations due to an increase in the refractive index of the media. The observed peak/dip shift was approximately twice that of LSPR from an isolated Au particle. We expect the present MIM substrate will be useful as a highly sensitive sensor in the pharmaceutical field.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1248/cpb.c21-00873 | DOI Listing |
Chem Pharm Bull (Tokyo)
February 2022
Graduate School of Pharmaceutical Sciences, Nagoya City University.
The free electrons inside precious metals such as Au vibrate when the surface of the metal is irradiated with an electromagnetic wave of an appropriate frequency. This oscillation is referred to as surface plasmon resonance (SPR), and the resonance frequency varies with permittivity of the medium around the metal. SPR sensors are widely applied in the fields of bioscience and pharmaceutical sciences, including biosensing for drug discovery, biomarker screening, virus detection, and testing for food safety.
View Article and Find Full Text PDFACS Omega
July 2018
Institute of Optoelectronic Sciences, National Taiwan Ocean University, No. 2 Pei-Ning Road, 202 Keelung, Taiwan.
In this paper, the coupled Ag-shell/dielectric-core nanorod for sensor application is investigated and the different dielectric core plasmonic metamaterial is adopted in our design. The operational principle is based on the concept of combining the lattice resonance, localized surface plasmon resonance (SPR), and cavity plasmon resonance modes within the nanostructure. The underlying mechanisms are investigated numerically by using the three-dimensional finite element method and the numerical results of coupled solid Ag nanorods are included for comparison.
View Article and Find Full Text PDFSensors (Basel)
April 2018
School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou 510006, Guangdong, China.
In this paper, a multichannel refractive index sensor based on a subwavelength metal⁻insulator⁻metal (MIM) waveguide coupled with tangent-ring resonators is proposed. When two tangent-ring resonators were placed above the MIM waveguide, Fano resonance with asymmetrical line shape appeared in the transmission spectrum due to the interference between the light⁻dark resonant modes. The sensitivity and figure of merit were as high as 880 nm/RIU and 964, respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!