Achieving patient-specific commissural alignment of transcatheter aortic valves is particularly important to ensure coronary reaccess after transcatheter aortic valve implantation. Nevertheless, in case of uncommon origin of coronary arteries, commissural alignment could be counterproductive. This case shows how alignment techniques could serve to intentionally misalign the neocommissures in this subset of patients. ().

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784705PMC
http://dx.doi.org/10.1016/j.jaccas.2021.12.002DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
12
aortic valve
8
commissural alignment
8
intentional misalignment
4
misalignment transcatheter
4
valve preserve reaccess
4
preserve reaccess coronaries
4
coronaries of anomalous
4
of anomalous origin
4
origin achieving
4

Similar Publications

Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.

View Article and Find Full Text PDF

In the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) era, implanting a larger-sized valve during the initial aortic valve replacement is important. For smaller aortic annuli, combining aortic annular and left ventricular outflow tract (LVOT) enlargement is essential. The Y-incision procedure helps achieve implantation of a 2-size larger valve.

View Article and Find Full Text PDF

Transcatheter Bailout: An Important Option During Complex Aortic Surgery.

Ann Thorac Surg Short Rep

December 2024

Division of Adult Cardiothoracic Surgery, Department of Surgery, University of California, San Francisco, San Francisco, California.

This report presents the case of a 66-year-old man with acute torrential aortic insufficiency after a Ross procedure 20 years earlier, a biologic aortic valve replacement 16 years earlier, and a transcatheter valve-in-valve 4 years earlier. He underwent third-time sternotomy, revealing that the pulmonary autograft was heavily calcified and frozen to the homograft. The previous transcatheter valve-in-valve was explanted.

View Article and Find Full Text PDF

We report a case of a woman who underwent mitral ring and tricuspid annuloplasty. Two months later, she presented with acute heart failure secondary to severe aortic regurgitation, which was a complication of the cardiac surgery. Given the high surgical risk of reoperation in this the patient, she underwent transcatheter aortic valve implantation, with a good result.

View Article and Find Full Text PDF

A 90-year-old man received a diagnosis of ascending aortic pseudoaneurysms after transcatheter aortic valve implantation (TAVI) using an Evolut PRO valve (Medtronic). Plug closure of the pseudoaneurysms was successfully performed, and the symptoms improved after the procedure. However, on postoperative day 4, the patient experienced sudden massive hemoptysis and died.