When employing minimal invasive extracorporeal circulation (MiECC), the removal of bubbles in the circuit is important to prevent air embolism. We investigated the bubble removal performance of the FHP oxygenator with a pre-filter and compared it with that of four oxygenators, including the Fusion oxygenator, Quadrox oxygenator, Inspire oxygenator, and FX oxygenator. A closed test circuit filled with an aqueous glycerin solution was used. Air injection (10 mL) was performed prior to the oxygenator, and the number and volume of the bubbles were measured at the inlet and outlet of each oxygenator. At the inlet of the five oxygenators, there were no significant differences in the total number of bubbles detected. At the outlet, bubbles were classified into two groups according to the bubble size: ≥100 μm and <100 μm. Tests were performed at pump flow rates of 4 and 5 L/min. For bubbles ≥100 μm, which are considered clinically detrimental, the FHP was the lowest number and volume of bubbles at both pump flow rates compared to the other oxygenators. Regarding the bubbles <100 μm, the number of bubbles was higher in the FHP than those in others; however, the volume of bubbles was significantly lower at 4 L/min and tended to be lower at 5 L/min. The use of the FHP with the pre-filter removed more bubbles ≥100 μm in the circuit than that by the other oxygenators.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02676591211064960DOI Listing

Publication Analysis

Top Keywords

bubble removal
8
oxygenator
7
comparison bubble
4
removal performances
4
performances membrane
4
membrane oxygenators
4
oxygenators pre-filter
4
pre-filter employing
4
employing minimal
4
minimal invasive
4

Similar Publications

Aim: To evaluate in vitro the antibacterial efficacy and cytocompatibility of different implant-decontamination methods, using both 2D and 3D peri-implant mucosa models.

Methods: Four decontamination methods [chlorhexidine (CHX), electrolytic treatment (GS), curcumin (CUR), xanthohumol (XN)] were compared in four independent experiments, three with a 2D peri-implant mucosa model on titanium surfaces and another on a 3D peri-implant mucosa model. These decontamination procedures were tested for their antibacterial effect using a multispecies biofilm model with Streptococcus oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis for 24 h.

View Article and Find Full Text PDF

Detection and imaging of dual miRNAs based on AND logic gates can improve the accuracy of the early diagnosis of disease. However, a single target may lead to false positive. Hence, this work rationally integrates hyperbranched rolling circle amplification (HRCA) with Cas12a by replacing the PAM sequence with a bubble to sensitively detect and image miRNA-10b and miRNA-21 based on the AND logic gate.

View Article and Find Full Text PDF

Elucidating molecular characteristics of organic compounds during ozone micro-bubbles treatment based on GC × GC-QTOF-MS and non-targeted analysis.

J Environ Manage

January 2025

College of Environment, Hohai University, Nanjing, 210098, PR China; Suzhou Research Institute, Hohai University, Suzhou, 215100, PR China; Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China. Electronic address:

The ozone micro-bubbles (OCBs) technology is increasingly gaining traction as a promising alternative method for organic compounds removal in wastewater. Nevertheless, there is a scarcity of literature addressing the molecular-level transformation of organic compounds during OCBs treatment. In this work, the secondary effluent from a wastewater treatment plant was treated with ozone milli-bubbles (OLBs) and OCBs, and the fate of organic compounds at the molecular level was investigated using comprehensive two-dimensional gas chromatography quadrupole time-of-flight mass spectrometry (GC × GC-QTOF-MS).

View Article and Find Full Text PDF

Purpose: To develop a simple tool to remove retained submacular perfluorocarbon liquid bubbles (R-PFCL) and to inject recombinant tissue plasminogen activator safely in subretinal space in submacular hematomas.

Method: A retrospective, interventional study was performed where a simple homemade micro-viscous fluid control was developed to gain access to subretinal space in a controlled way. The rubber cap of the plunger of a 1-mL syringe was cut; this cut rubber cap of the plunger was fitted inside an empty 1-mL tuberculin syringe, and its end was fitted with the tubings of viscous fluid control of the vitrectomy machine.

View Article and Find Full Text PDF

Partial oxidation of methane (POM) is achieved by forming air-methane microbubbles in saltwater to which an alternating electric field is applied using a copper oxide foam electrode. The solubility of methane is increased by putting it in contact with water containing dissolved KCl or NaCl (3%). Being fully dispersed as microbubbles (20-40 µm in diameter), methane reacts more fully with hydroxyl radicals (OH·) at the gas-water interface.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!