High-definition transcranial direct current stimulation modulates eye gaze on emotional faces in college students with alexithymia: An eye-tracking study.

Prog Neuropsychopharmacol Biol Psychiatry

Department of Neurology, The First Affiliated Hospital of Anhui Medical University, The School of Mental Health and Psychological Sciences, Anhui Medical University, Hefei 230032, Anhui Province, China; Anhui Province Key Laboratory of Cognition and Neuropsychiatric Disorders, Hefei 230032, China; Collaborative Innovation Center for Neuropsychiatric Disorders and Mental Health, Anhui Medical University, Hefei 230032, China; Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei 230088, China. Electronic address:

Published: June 2022

Background: Atypical eye gaze on emotional faces is a core feature of alexithymia. The inferior frontal gyrus (IFG) is considered to be the neurophysiological basis of alexithymia-related emotional face fixation. Our aim was to examine whether anodal high-definition transcranial direct current stimulation (HD-tDCS) administered to the right (r)IFG would facilitate eye gaze of emotional faces in alexithymia individuals.

Method: Forty individuals with alexithymia were equally assigned to anodal or sham HD-tDCS of the rIFG according to the principle of randomization. The individuals then completed a free-viewing eye tracking task (including happy, sad, and neutral faces) before and after 5 consecutive days of stimulation (twice a day).

Results: The results showed that twice a day anodal HD-tDCS of the rIFG significantly increased the fixation time and fixation count of the eye area on happy and neutral faces, but there was no significant effect on sad faces. According to the temporal-course analysis, after the intervention, the fixation time on neutral faces increased significantly at almost all time points of the eye tracking task. For happy faces, the improvement was demonstrated between 500 and 1000 ms and between 2500 and 3500 ms. For sad faces, the fixation time improved but not significantly.

Conclusions: Applying high-dose anodal HD-tDCS to the rIFG selectively facilitated eye gaze in the eye area of neutral and happy faces in individuals with alexithymia, which may improve their face processing patterns.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pnpbp.2022.110521DOI Listing

Publication Analysis

Top Keywords

eye gaze
16
gaze emotional
12
emotional faces
12
hd-tdcs rifg
12
neutral faces
12
fixation time
12
faces
10
high-definition transcranial
8
transcranial direct
8
direct current
8

Similar Publications

Explicit metrics for implicit emotions: investigating physiological and gaze indices of learner emotions.

Front Psychol

December 2024

Departent of Learning, Data-Analytics and Technology, Faculty of Behavioural, Management and Social Sciences, University of Twente, Enschede, Netherlands.

Learning experiences are intertwined with emotions, which in turn have a significant effect on learning outcomes. Therefore, digital learning environments can benefit from taking the emotional state of the learner into account. To do so, the first step is real-time emotion detection which is made possible by sensors that can continuously collect physiological and eye-tracking data.

View Article and Find Full Text PDF

The processing literature provides some evidence that heritage Spanish speakers process gender like monolinguals, since gender-marking in definite articles facilitates their lexical access to nouns, albeit these effects may be reduced relative to speakers who learned the language as majority language. However, previous studies rely on slowed-down speech, which leaves open the question of how processing occurs under normal conditions. Using naturalistic speech, our study tests bilingual processing of gender in determiners, and in word-final gender vowels.

View Article and Find Full Text PDF

Assessment of Photoreceptor Recovery and Visual Function Utilizing Adaptive Optics and Microperimetry in Patients with Surgically Closed Macular Holes.

Photodiagnosis Photodyn Ther

December 2024

Department of Ophthalmology, Tianjin Medical University General Hospital, Tianjin, China, Ministry of Education International Joint Laboratory of Ocular Diseases, Tianjin, China, Tianjin Key Laboratory of Ocular Trauma, Tianjin, China, Tianjin Institute of Eye Health and Eye Diseases, Tianjin, China, China-UK "Belt and Road" Ophthalmology. Electronic address:

Background: This study investigated the association between photoreceptor structural restoration and visual function outcomes in patients undergoing surgery for closed macular holes (MHs). Using adaptive optics scanning laser ophthalmoscopy (AOSLO) and microperimetry, we aimed to provide a more detailed understanding of photoreceptor recovery and visual improvement in closed MHs.

Methods: We conducted a retrospective observational study of 31 eyes of 28 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling to treat idiopathic MHs.

View Article and Find Full Text PDF

The interplay between motor cost and self-efficacy related to walking across terrain in gaze and walking decisions.

Sci Rep

December 2024

Biomedical Physiology and Kinesiology, Simon Fraser University, 8888 University Drive, Burnaby, BC, V5A 1S6, Canada.

Motor behaviours, like where to step and which path to walk, rely on gaze shifts to gather visual information necessary to decide the next action. Factors influencing both gaze and walking decisions are poorly understood. Here we had people choose between two paths to determine how a person's belief in their ability to walk across different terrains (i.

View Article and Find Full Text PDF

Closed globe refixation of the IOL-bag complex with the ab-externo 8-exit-4-point fixation technique.

Indian J Ophthalmol

December 2024

Department of Vitreo-Retina, Narayana Nethralaya, Bengaluru, Karnataka, India.

Intraocular lens (IOL) dislocation is not an uncommon complication and often requires surgical intervention, depending on the status of capsular bag support. Conventionally, posterior dislocation of a foldable IOL or the IOL-bag complex warrants their removal as foldable IOLs are not ideal for sulcus placement. The technique presented here describes using quadrilateral sutures to refix looped haptic IOLs at the ciliary sulcus with or without a bag complex.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!