Memsorb™ (DMF Medical, Halifax, Canada) is a novel device based upon membrane oxygenator technology designed to eliminate CO from exhaled gas when using a circle anesthesia circuit. Exhaled gases pass through semipermeable hollow fibers and sweep gas flowing through these fibers creates a diffusion gradient for CO removal. In vivo Memsorb™ performance was tested during target-controlled closed-circuit anesthesia (TCCCA) with desflurane in O/air using a Zeus IE® anesthesia workstation (Dräger, Lübeck, Germany). Clinical care protocols for using this novel device were guided by in vitro performance results from a prior study (submitted simultaneously). After IRB approval, written informed consent was obtained from 10 ASA PS I-III patients undergoing robot-assisted radical prostatectomy. TCCCA targets were 39% inspired O concentration (FO) and 5.0% end-expired desflurane concentration (Fdes). Minute ventilation (MV) was adjusted to maintain 4.5-6.0% FCO. The O/air (40% O) sweep flow into the Memsorb™ was manually adjusted in an attempt to keep inspired CO concentration (FCO) ≤ 0.8%. The following data were collected: FO, Fdes, FCO, FCO, MV, fresh gas flow (FGF, O and air), sweep flow, and cumulative desflurane usage (Vdes). Vdes of the Zeus IE®-Memsorb™ combination was compared with historical Vdes observed in a previous study when soda lime (DrägerSorb 800 +) was used. Results are reported as median and inter-quartiles. A combination of manually adjusting sweep flow (26 [21,27] L/min) and MV sufficed to maintain FCO ≤ 0.8% and FCO ≤ 6.0%, except in one patient in whom the target Zeus IE® FGF had to be increased to 0.7 L/min for 6 min. FO and Fdes were maintained close to their targets. Zeus IE® FGF after 5 min was 0 [0,0] mL/min. Average Vdes after 50 min was higher with Memsorb™ (20.3 mL) compared to historical soda lime canister data (12.3 mL). During target-controlled closed-circuit anesthesia in patients undergoing robot-assisted radical prostatectomy, the Memsorb™ maintained FCO ≤ 0.8% and FCO ≤ 6.0%, and FO remained close to target. Modest amounts of desflurane were lost with the use of the Memsorb™. The need for adjustments of sweep flow, minute ventilation, and occasionally Zeus IE® FGF indicates that the Memsorb™ system should preferentially be integrated into an automated closed-loop system.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-022-00808-2DOI Listing

Publication Analysis

Top Keywords

zeus ie®
16
sweep flow
16
ie® fgf
12
memsorb™
8
novel device
8
target-controlled closed-circuit
8
closed-circuit anesthesia
8
patients undergoing
8
undergoing robot-assisted
8
robot-assisted radical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!