Background: Ascending aortic pseudoaneurysms (AAPs) constitute a rare, albeit potentially dangerous, condition that occurs in up to 13% of patients after cardiac or aortic surgeries. For patients with a history of cardiac surgery, repeat thoracotomy poses additive risks. The high morbidity and mortality rates associated with the surgical management of AAPs have led to the development of transcatheter approaches.

Case Report: We report a case of AAP percutaneous closure at the site of aortic cannulation with an ASO device in a post-CABG 65-year-old man, who refused surgery.

Conclusion: The use of the Amplatzer Atrial Septal Defect Occluder (ASO) device represents an acceptable alternative to surgery in treatment of Ascending aortic pseudoaneurysms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8807733PMC
http://dx.doi.org/10.1186/s42155-021-00280-0DOI Listing

Publication Analysis

Top Keywords

ascending aortic
8
aortic pseudoaneurysms
8
aso device
8
cardiac solution
4
solution vascular
4
vascular scenario!
4
scenario! background
4
background ascending
4
aortic
4
pseudoaneurysms aaps
4

Similar Publications

We present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.

View Article and Find Full Text PDF

Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.

Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.

View Article and Find Full Text PDF

The transcatheter management of complex cardiovascular diseases has significantly evolved, offering less invasive alternatives to traditional surgical interventions. In this report we describe 2 cases of patients who developed ascending aortic pseudoaneurysms soon after coronary artery bypass grafting. With meticulous computed tomography angiography planning and with live intracardiac echography, these patients underwent successful transcatheter repair using a 6/4-mm Amplatzer Duct Occluder II (Abbott) vascular plug.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!