A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surface plasmon resonance biosensor based on graphene layer for the detection of waterborne bacteria. | LitMetric

As a result of the risks that waterborne bacteria bring to the human body, identifying them in drinking water has become a global concern. In this article, a highly sensitive surface plasmon resonance (SPR) biosensor consisting of prism, Ag, graphene, affinity layer and sensing medium is proposed for rapid detection of the waterborne bacteria. Four SPR-based sensors are first studied with the structures prism/Ag/sensing medium, prism/Ag/affinity layer/sensing medium, prism/Ag/graphene/sensing medium, and prism/Ag/graphene/affinity layer/sensing medium. The latter structure is found to have the highest sensitivity so it is considered for further investigations. Four different commonly used prisms are then demonstrated which are N-FK51A, 2S2G, SF10 and BK7. The structure with the prism N-FK51A is found to correspond to the highest sensitivity so it is considered for further investigations. The structure parameters are then optimized. The proposed SPR sensor can achieve high sensitivity of about 221.63 °/RIU for Escherichia coli and 178.12 °/RIU for Vibrio cholera bacteria with an average value of 199.87 °/RIU. We believe that the proposed structure will open a new window in the field of microorganism detections.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbio.202200001DOI Listing

Publication Analysis

Top Keywords

waterborne bacteria
12
surface plasmon
8
plasmon resonance
8
detection waterborne
8
layer/sensing medium
8
highest sensitivity
8
sensitivity considered
8
considered investigations
8
medium
5
resonance biosensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!