Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
V-shaped braid stents (VBSs), as highly retrievable and flexible nitinol stents, are extensively applied in endovascular diseases. They also cause less damage to vessel wall compared to tube-cutting stents. However, poor performance of VBS or suboptimal operation can give rise to unwanted clinical situations such as thrombosis and intimal hyperplasia. Therefore, research on designing factors affecting the performance of these devices is of great significance. Furthermore, simulation of stenting process can help designers understand the interactions of stents and vessel wall to reduce time to market. Thus, finite element analysis (FEA) and bench test are performed taking into account both designing factors and stenting process of VBS, including development of parametric modeling tool, research on the relationships among structural parameters and radial force, exploration of the interactions of VBS and vessel wall and pulsating load effect. This research was performed using a commercial solver Abaqus/standard with a user material subroutine (UMAT/nitinol). Structural parameters of VBS, unit-cell height and wire diameter have significant impacts on radial force, unit-cell number has slight influence on radial force, and arc diameter has almost negligible impact on radial force. Without pulsatile load, maximum stress and strain always occur in arc position; however, in pulsatile load, maximum stress and strain are gradually transformed to strut position. The stress created near vessel wall and VBS interface is higher than interaction stress due to pulsating load. The obtained result provided valuable information on the structural design of stents as well as the effects of stent on vessel wall and that vessel wall on stent deformation.[Formula: see text].
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/09544119221076946 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!