A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of mechanical behaviors and improved design of V-shaped braid stents. | LitMetric

Investigation of mechanical behaviors and improved design of V-shaped braid stents.

Proc Inst Mech Eng H

Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.

Published: February 2022

V-shaped braid stents (VBSs), as highly retrievable and flexible nitinol stents, are extensively applied in endovascular diseases. They also cause less damage to vessel wall compared to tube-cutting stents. However, poor performance of VBS or suboptimal operation can give rise to unwanted clinical situations such as thrombosis and intimal hyperplasia. Therefore, research on designing factors affecting the performance of these devices is of great significance. Furthermore, simulation of stenting process can help designers understand the interactions of stents and vessel wall to reduce time to market. Thus, finite element analysis (FEA) and bench test are performed taking into account both designing factors and stenting process of VBS, including development of parametric modeling tool, research on the relationships among structural parameters and radial force, exploration of the interactions of VBS and vessel wall and pulsating load effect. This research was performed using a commercial solver Abaqus/standard with a user material subroutine (UMAT/nitinol). Structural parameters of VBS, unit-cell height and wire diameter have significant impacts on radial force, unit-cell number has slight influence on radial force, and arc diameter has almost negligible impact on radial force. Without pulsatile load, maximum stress and strain always occur in arc position; however, in pulsatile load, maximum stress and strain are gradually transformed to strut position. The stress created near vessel wall and VBS interface is higher than interaction stress due to pulsating load. The obtained result provided valuable information on the structural design of stents as well as the effects of stent on vessel wall and that vessel wall on stent deformation.[Formula: see text].

Download full-text PDF

Source
http://dx.doi.org/10.1177/09544119221076946DOI Listing

Publication Analysis

Top Keywords

vessel wall
24
radial force
16
v-shaped braid
8
braid stents
8
designing factors
8
stenting process
8
structural parameters
8
pulsating load
8
pulsatile load
8
load maximum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!