The purposes of the current study were to introduce a Mescher-Garwood (MEGA) semi-adiabatic spin-echo full-intensity localization (MEGA-sSPECIAL) sequence with macromolecule (MM) subtraction and to compare the test-retest reproducibility of γ-aminobutyric acid (GABA) measurements at 7 T using the sSPECIAL and MEGA-sSPECIAL sequences. The MEGA-sSPECIAL editing scheme using asymmetric adiabatic and highly selective Gaussian pulses was used to compare its GABA measurement reproducibility with that of short echo-time (TE) sSPECIAL. Proton magnetic resonance spectra were acquired in the motor cortex (M1) and medial prefrontal cortex (mPFC) using the sSPECIAL (TR/TE = 4000/16 ms) and MEGA-sSPECIAL sequences (TR/TE = 4000/80 ms). The metabolites were quantified using LCModel with unsuppressed water spectra. The concentrations are reported in institutional units. The test-retest reproducibility was evaluated by scanning each subject twice. Between-session reproducibility was assessed using coefficients of variation (CVs), Pearson's r correlation coefficients, and intraclass correlation coefficients (ICCs). Intersequence agreement was evaluated using Pearson's r correlation coefficients and Bland-Altman plots. Regarding GABA measurements by sSPECIAL, the GABA concentrations were 0.92 ± 0.31 (IU) in the M1 and 1.56 ± 0.49 (IU) in the mPFC. This demonstrated strong between-session correlation across both regions (r = 0.81, p < 0.01; ICC = 0.82). The CVs between the two scans were 21.8% in the M1 and 10.2% in the mPFC. On the other hand, the GABA measurements by MEGA-sSPECIAL were 0.52 ± 0.04 (IU) in the M1 and 1.04 ± 0.24 (IU) in the mPFC. MEGA-sSPECIAL demonstrated strong between-session correlation across the two regions (r = 0.98, p < 0.001; ICC = 0.98) and lower CVs than sSPECIAL, providing 4.1% in the M1 and 5.8% in the mPFC. The MEGA-editing method showed better reproducibility of GABA measurements in both brain regions compared with the short-TE sSPECIAL method. Thus it is a more sensitive method with which to detect small changes in areas with low GABA concentrations. In GABA-rich brain regions, GABA measurements can be achieved reproducibly using both methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285498PMC
http://dx.doi.org/10.1002/nbm.4706DOI Listing

Publication Analysis

Top Keywords

correlation coefficients
12
γ-aminobutyric acid
8
short echo-time
8
test-retest reproducibility
8
gaba measurements
8
mega-sspecial sequences
8
pearson's correlation
8
acid measurement
4
measurement human
4
human brain
4

Similar Publications

This study examined the relationship between change in symptom severity and personal recovery in patients with severe mental illness (SMI). Forty-nine outpatients at Mentrum/Arkin, Amsterdam, the Netherlands, were assessed at baseline and 3 years later, using the Brief Psychiatric Rating Scale and the Mental Health Recovery Measure. Correlation coefficients and linear regression analyses were used.

View Article and Find Full Text PDF

Background: Evidence-based medicine and patient-reported outcome measures (PROMs) are helpful tools in the wound care field, but few studies correlating quality of life (QoL) changes with objective changes exist.

Objective: To investigate the QoL changes following the shift from primary dressings alone to elastic compression bandages in patients with a new diagnosis of vascular skin ulcer, and to evaluate a possible correlation between objective and subjective changes.

Materials And Methods: This study included 122 patients with a new diagnosis of vascular skin ulcer, who had previously used only primary dressings alone.

View Article and Find Full Text PDF

Objectives: Our study aimed to compare signal characteristics of subdural electrodes (SDE) and depth stereo EEG placed within a 5-mm vicinity in patients with drug-resistant epilepsy. We report how electrode design and placement collectively affect signal content from a shared source between these electrode types.

Methods: In subjects undergoing invasive intracranial EEG evaluation at a surgical epilepsy center from 2012 to 2018, stereo EEG and SDE electrode contacts placed within a 5-mm vicinity were identified.

View Article and Find Full Text PDF

A convenient but efficient tool for evaluating dietary intakes in Chinese professional athletes has yet to be established. The aim of this study was to assess the validity of a short semi-quantitative food frequency questionnaire (FFQ) through comparison with 3-day weighed food records (3DWFRs) and corresponding serum biomarkers from a cohort of 102 professional athletes, while also evaluating its reproducibility. The relative validity was assessed using Spearman correlation coefficients, cross-quintiles classification, weighted kappa, and Bland-Altman analysis, while reproducibility was evaluated using the Spearman correlation coefficients and intraclass correlation coefficient (ICC) between two FFQs.

View Article and Find Full Text PDF

Introduction: Measurement of repeatability and reproducibility (R&R) is necessary to realize the full potential of positron emission tomography (PET). Several studies have evaluated the reproducibility of PET using 18F-FDG, the most common PET tracer used in oncology, but similar studies using other PET tracers are scarce. Even fewer assess agreement and R&R with statistical methods designed explicitly for the task.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!